5-34
5-2-3.
SERVICE MODE
1.
Emergence Memory Address
Page C
Address 38 to 43
Address
Contents
38
EMG code when first error occurs
3A
Upper: MSW code when shift starts when first error
occurs
Lower: MSW code when first error occurs
3B
Lower: MSW code to be moved when first error
occurs
3C
EMG code when second error occurs
3E
Upper: MSW code when shift starts when second
error occurs
Lower: MSW code when second error occurs
3F
Lower: MSW code to be moved when second error
occurs
40
EMG code when last error occurs
42
Upper: MSW code when shift starts when last error
occurs
Lower: MSW code when last error occurs
43
Lower: MSW code to be moved when last error
occurs
When no error occurs in this unit, data “00” is written in the above
addresses (38 to 43). when first error occurs in the unit, the data
corresponding to the error is written in the first emergency ad-
dress (38 to 3B). In the same way, when the second error occurs,
the data corresponding to the error is written in the second emer-
gency address (3C to 3F).
Finally, when the last error occurs, the data corresponding to the
error is written in the last emergency address (40 to 43).
Note 2:
After completing adjustments, be sure to initialize the
data of addresses 38 to 43 to “00”.
Initializing method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: C, address: 38, set data: 00, and press the PAUSE
button.
3) Select address: 39 to 43 and set data “00” into them in the
same way as in address: 10.
4) Select page: 0, address: 01, and set data: 00.
2.
EMG Code (Emergency Code)
Codes corresponding to the errors which occur are written in ad-
dresses 38, 3C, 3E. The type of error indicated by the code are
shown in the following table.
Code
Error Type
00
No error (Initial state)
10
Loading motor time-out during LOAD
11
Loading motor time-out during UNLOAD
20
Error during tape take up
22
T reel error
23
S reel error
25
Reel motor error
30
Error during normal capstan rotation
40
FG error during drum start-up
42
FG error during normal drum rotation
50
DEW detection
52
Wet DEW detection
70
Cassette compartment LOAD error
71
Cassette compartment UNLOAD error
72
Retry error because something is caught
Содержание DVCAM DSR-50
Страница 55: ...DSR 50 50P 4 9 4 10 REC PB AMP RP 234 2 1 ...
Страница 75: ...DSR 50 50P 4 49 4 50 VIDEO D A CONVERTER SYNC SHIFTER AUDIO A D D A CONVERTER AUDIO DSP TIME CODE IN OUT DI 73 ...
Страница 107: ...DSR 50 50P 4 113 4 114 DC DC CONVERTER MOTOR DRIVE CM 59 49 48 33 32 17 16 1 2 ...
Страница 111: ...DSR 50 50P 4 121 4 122 USER CONTROL FR 157 ...
Страница 115: ...DSR 50 50P 4 129 4 130 VIDEO AUDIO IN OUT JK 169 ...
Страница 280: ... 378 DSR 50 50P 9 929 851 12 Sony EMCS Co 2006C0500 1 2006 3 Published by DI Technical Support Department ...