5-47
3-2.
SYSTEM CONTROL SYSTEM
ADJUSTMENTS
1.
Initializing the C, D, E Page Data
Note 1:
If “Initializing the C, D, E Page Data” is performed, all
data of the C page, D page and E page will be initialized.
Note 2:
If the C, D, E page data has been initialized, “Modifica-
tion of C, D, E page Data” and all adjustments need to be
performed again.
Mode
E-E
Signal
Arbitrary
Adjustment Page
C
Adjustment Address
00 to DF
Adjustment Page
D
Adjustment Address
10 to 3F
Adjustment Page
E
Adjustment Address
10 to E8
5.
Modification of C, D, E, Page Data
If the C, D, E page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note :
If copy the data built in the different model, this set may
not operate.
3) When changing the data, press the PAUSE button of the ad-
justing remote commander each time when setting new data
to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
5) After completing “Modification of C, D, E Page Data”, select
page: 0, address: 01, and set data: 00. Also perform all adjust-
ments.
2.
Input of C Page Initial Data
Input method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 80, set data: 0C, and press the PAUSE
button on the adjustment remote commander.
3) Select page: 3, address: 80, and check that the data change to
“1C”.
4) Press the RESET switch at the bottom of the set using a thin
and long pin.
5) Modify the C page data. (Refer to C page table)
3.
Input of D Page Initial Data
Input method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 80, set data: 0D, and press the PAUSE
button on the adjustment remote commander.
3) Select page: 3, address: 80, and check that the data change to
“1D”.
4) Press the RESET switch at the bottom of the set using a thin
and long pin.
5) Modify the D page data. (Refer to D page table)
4.
Input of E Page Initial Data
Input method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 9, address: 00, set data: 2D, and press the PAUSE
button on the adjustment remote commander.
3) Select page: 9, address: 01, set data: 2D, and press the PAUSE
button.
4) Select page: 9, address: 02, and check that the data change to
“01”.
5) Disconnect the adjustment remote commander, and turn the
POWER switch OFF.
6) Turn off the regulated power supply connected to the DCIN
terminal once, and turn it on again.
7) Check that the date, time, available tape capacity, and format
are displayed on the display window (monochrome LCD) of
the set.
8) Turn the POWER switch ON.
9) Press the RESET switch at the bottom of the set using a thin
and long pin.
10) Modify the E page data. (Refer to E page table)
Содержание DVCAM DSR-50
Страница 55: ...DSR 50 50P 4 9 4 10 REC PB AMP RP 234 2 1 ...
Страница 75: ...DSR 50 50P 4 49 4 50 VIDEO D A CONVERTER SYNC SHIFTER AUDIO A D D A CONVERTER AUDIO DSP TIME CODE IN OUT DI 73 ...
Страница 107: ...DSR 50 50P 4 113 4 114 DC DC CONVERTER MOTOR DRIVE CM 59 49 48 33 32 17 16 1 2 ...
Страница 111: ...DSR 50 50P 4 121 4 122 USER CONTROL FR 157 ...
Страница 115: ...DSR 50 50P 4 129 4 130 VIDEO AUDIO IN OUT JK 169 ...
Страница 280: ... 378 DSR 50 50P 9 929 851 12 Sony EMCS Co 2006C0500 1 2006 3 Published by DI Technical Support Department ...