5-54
5.
CLK DELAY and AEQ Adjustment (RP-234 Board)
Mode
Recording and playback
Signal
Color bar
Measurement Point
Displayed data of page: 3, address:
03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
18, 19, 1B, 1C, 21, 73
Specified Value
“ 00 ”
Adjusting method:
1) Record the color bar signal in the optional tape about 2 minutes.
2) Select page: 0, address: 01, and set data: 01.
3) Select page: C, address: 54, set data: CC, and press the PAUSE
button of the adjustment remote commander.
4) Select page: 3, address: 1D, set data: 21, and press the PAUSE
button.
5) Play back the recorded section.
6) Select page: 3, address: 01, set data: 07, and press the PAUSE
button.
7) Select page: 3, address: 02, and check that the data changes to
“ 00 ”.
8) Select page: 3, address: 03, and check that the data is “ 00 ”.
9) Select page: 3, address: 1D, set data: 20, and press the PAUSE
button.
10) Select page: C, address: 54, set data: 00, and press the PAUSE
button.
11) Select page: 0, address: 01, and set data: 00.
6.
PLL f
0
Final Adjustment (RP-234 Board)
Mode
E-E
Signal
No signal
Measurement Point
Displayed data of page: 3, address:
03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
1F, 20, 22, 47
Specified Value
“ 00 ”
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 01, set data: 30, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 3, address: 02, and check that the data changes to
“ 00 ”.
4) Select page: 3, address: 03, and check that the data is “ 00 ”.
5) Select page: 0, address: 01, and set data: 00.
3-4. VIDEO SYSTEM ADJUSTMENTS
3-4-1. JC-20 Board Adjustment
1.
VFD SPCK Adjustment (JC-20 Board)
Mode
E-E
Signal
No signal
Measuring Point
Pin
5
of IC3302 (CL3305)
Measuring Instrument
Frequency counter
Adjustment Element
CT3300
Specified value
f = 13500000 ± 20 Hz
Adjusting method:
1) Set the VFD SPCK frequency (f) to the specified value using
CT3300.
2.
A/D Converter Reference Voltage Adjustment (1)
(JC-20 Board)
Mode
E-E
Signal
Arbitrary
Measuring Point
Pin
5
of IC1105 (CL1170)
Measuring Instrument
Digital voltmeter
Adjustment Element
RV1100
Specified value
A = 2.83 ± 0.01 Vdc
Adjusting method:
1) Set the VRT voltage (A) to the specified value using RV1100.
3.
A/D Converter Reference Voltage Adjustment (2)
(JC-20 Board)
Mode
E-E
Signal
Arbitrary
Measuring Point
Pin
3
of IC1105 (CL1169)
Measuring Instrument
Digital voltmeter
Adjustment Element
RV1101
Specified value
A = 0.96 ± 0.01 Vdc
Adjusting method:
1) Set the VBT voltage (A) to the specified value using RV1101.
Содержание DVCAM DSR-50
Страница 55: ...DSR 50 50P 4 9 4 10 REC PB AMP RP 234 2 1 ...
Страница 75: ...DSR 50 50P 4 49 4 50 VIDEO D A CONVERTER SYNC SHIFTER AUDIO A D D A CONVERTER AUDIO DSP TIME CODE IN OUT DI 73 ...
Страница 107: ...DSR 50 50P 4 113 4 114 DC DC CONVERTER MOTOR DRIVE CM 59 49 48 33 32 17 16 1 2 ...
Страница 111: ...DSR 50 50P 4 121 4 122 USER CONTROL FR 157 ...
Страница 115: ...DSR 50 50P 4 129 4 130 VIDEO AUDIO IN OUT JK 169 ...
Страница 280: ... 378 DSR 50 50P 9 929 851 12 Sony EMCS Co 2006C0500 1 2006 3 Published by DI Technical Support Department ...