3-4-5a. R EC C Recording Cu rrent Adjustment
( R P-29 Board)
Mode:
Recording
Tape:
MP tape
Connection:
Connect the following three p oints with
jumpers.
•
RP-2 9 board pin
CD
( REC ATF ) and pin
®
( REG
GND)
•
RP-2 9 board pin
Q)
( REC AFM) and pin
@
( R EG GND)
•
RP-29 board pin
@)
( REC Y) and pin
�
\ ( REG
GND)
Adjustment Procedure:
1 ) Remove the solder at RP-29 board pin
Q)
( REC C) as
shown in Fig. 3 - 1 4 so that the pin is completely off the
land, and input a 7 5 0 kHz, 0.4 ±0.0 1 Vp-p sine wave
from an RC oscillator.
2 ) Connect the oscilloscope t o RP-29 board pin
(?)
and
adjust to 4 2 mVp-p with RV5 08. ( Fig. 3 - 1 5 )
RP-29 board pin
@
Fig.
3- 15
RC oscillator
(
l50 kHz
)
Sine wave
0.4
±0.01
Vp·p
Fig.
3- 14
RP·29 board
pin
@
42 m Vp-p
REC C recording current adjustment
3-4-5b. REC C Recording Current Adjustment (simpl ified
method )
Mode:
Recording
Subject:
Color-bar chart (standard frame)
Adjustment Procedure:
Connect the oscilloscope to RP-29
board pin
G),
and memorize red level.
Connect the oscilloscope to RP-29 board pin
([?; ,
and
adjust RV5 08 so that red level is 1 / 1 0 against the level
at pin
(i).
(Fig. 3- 1 6 )
Fig.
3- 16
Red
REC C recording current adjustment
(simplified method)
-