VIDEO ADJUSTMENTS
The measuring instruments listed below are used for a djust
m ent of the video section.
Equipment Required:
1 ) Monitor TV
2 ) A C adapter
(
Modification i s needed for AC-V8UC;
)
the procedure is found under Camera
Adjustment 1 -3 , 3) AC-V8 UC Modifi
cation Procedure.
3 ) Dual-trace oscilloscope, band range over 1 0 MHz, with
delay mode (Unless otherwise indicated, use a 1 0 : 1
probe.)
4) Frequency counter
5 ) Track shift
&
monitor j ig
Part No.: J-6080-843-A
6 ) Digital voltmeter
7 ) Audio generator
8) Audio level m eter
9) Au,dio distortion meter
1 0) Audio attenuator
1 1 ) Stable DC power supply
1 2) Alignment tape
For tracking adjustment : WR5- 1 N
Part No.: 8-967-995-0 1
For video frequency response adjustment : W R5 -2 N
Part No. : 8-967-995- 1 1
For operation check: W R5 -3 NS
Part No.: 8-967-995-2 1
1 3 ) Tape end detection filter
Part No. : J-6 080-848-A
1 4) Playback equipment (EV-A300, EV-S700, etc.)
Equipment Connection:
Refer to the section on Camera Adjustment " l -3 . Track
shift
&
m onitor j ig connection procedure" for the connec
t io n and recording procedures for the,track shift
&
monitor
j ig. Also, refer to "2-4. Tape Path Adjustment'', "2-4- 1 .
Preparations for Adjustment" for playback procedure.
Refer to the Service Manual for the playback equipment for
the connection when using playback equipment to measure.
Measurement Procedure:
When using the oscilloscope probe to measure chip com
p onents, solder a lead to the location to be measured and
c onnect the probe. to the lead.
-70-
Chip component
Oscilloscope probe
Measurement procedure