Page 162 SonicWALL TELE3 SP Administrator’s Guide
Getting Started with High Availability
Before Configuring High Availability
Before attempting to configure two SonicWALLs as a
High Availability
pair, check the
following requirements:
•
You have two (2) SonicWALL Internet Security Appliances. The
High Availability
pair
must consist of two identical SonicWALL models.
•
You have at least one (1) valid, static IP address available from your Internet Service
Provider (ISP). Two (2) valid, static IP addresses are required to remotely manage both the
primary SonicWALL and the backup SonicWALL.
Note
: SonicWALL
High Availability
does not support dynamic IP address assignment from
your ISP.
•
Each SonicWALL in the
High Availability
pair must have the same firmware version
installed.
•
Each SonicWALL in the
High Availability
pair must have the same upgrades and
subscriptions enabled. If the backup unit does not have the same upgrades and
subscriptions enabled, these functions are not supported in the event of a failure of the
primary SonicWALL.
Network Configuration for High Availability Pair
The following diagram illustrates the network configuration for a
High Availability
pair:
All SonicWALL ports being used must be connected together with a hub or switch. Each
SonicWALL must have a unique LAN IP Address on the same LAN subnet. If each SonicWALL
has a unique WAN IP Address for remote management, the WAN IP Addresses must be in the
same subnet.
Note
: The two SonicWALLs in the
High Availability
pair sends “heartbeats” over the LAN
network segment. The
High Availability
feature does not function if the LAN ports are not
connected.