I2773-4.
4
en
47
Somat eDAQ
lite
FCS Setup
Set Master Sample Rate
Specify the master sample rate (MSR) as either 100000 Hz, the
standard MSR for the eDAQ
lite
, or 98304 Hz, provided to support
power of two sample rates. Data sample and data storage rates must
be integer divisors of the MSR. The eDAQ
lite
stores the MSR in
nonvolatile memory for access only after an eDAQ
lite
reset.
Therefore, TCE initiates a programmed reset of the eDAQ
lite
unit
when the parameter changes.
Set Reset Options
Control options for initiating system resets. The only applicable option
is the no new run on FCS error reset option which prevents the
eDAQ
lite
from attempting to start a new test run when a serious error
forces a reset. For normal operation, do not select this option so that
the eDAQ
lite
can attempt to salvage as much of the test run as
possible. This option is not available when the test is initialized.
Set Clock
Set the real time clock on the eDAQ
lite
unit based on the current date
and time setting on the host PC.
Reset
Perform a programmed reset of the eDAQ
lite
unit. Use this option
only if absolutely necessary, such as when the system is not
responding.
Delete RAM Disk Files
Delete all resident test and data files from the RAM disk. Only use this
option if there is no test initialized on the eDAQ
lite
and all test data
has been safely uploaded from the eDAQ
lite
.
Format RAM Disk
Format the RAM disk on the eDAQ
lite
unit and erase all files,
including some test data files, from the RAM disk. This option is
available at all times even while a test is running. Because the
eDAQ
lite
formats the RAM disk in the normal process of test
initialization, formatting the RAM disk is not typically necessary.
Diagnostics
Access commands for troubleshooting purposes.
Test FTP
Perform a diagnostic test on the eDAQ
lite
file transfer process (FTP)
functionality. This option is not available when a test is initialized.
Check RAM Disk
Check the integrity of the eDAQ
lite
RAM disk.
Upload Log
Save the eDAQ
lite
log, which contains messages, warnings and
errors from TCE and the eDAQ
lite
, to a PC disk file.
Preferences
Communication Preferences
Configure the Ethernet communications with the eDAQ
lite
.
General Preferences
Configure TCE application preferences.
FCS Specific Preferences
Configure TCE preferences specific to the target eDAQ
lite
.
Remote Test Run Control
Configure the preferences for using remote control.
Scope and Spectrum
Configure the settings for scope and spectrum displays.
Run Time Display
Configure the settings for run-time displays.
Group DVM Display
Configure the settings for group DVM displays.
Menu
Menu Option
Description
Section
HBM: public
Содержание eDAQlite
Страница 1: ...User Manual English Deutsch Espanol I2773 4 4 en HBM public Somat eDAQlite with TCE Software ...
Страница 2: ...Somat eDAQlite 2 I2773 4 4 en HBM public ...
Страница 16: ...Somat eDAQlite 16 I2773 4 4 en HBM public ...
Страница 22: ...Somat eDAQlite 22 I2773 4 4 en HBM public ...
Страница 88: ...Somat eDAQlite 88 I2773 4 4 en HBM public ...
Страница 106: ...Somat eDAQlite 106 I2773 4 4 en HBM public ...
Страница 128: ...Somat eDAQlite 128 I2773 4 4 en HBM public ...
Страница 190: ...Somat eDAQlite 190 I2773 4 4 en HBM public ...
Страница 202: ...Somat eDAQlite 202 I2773 4 4 en HBM public ...
Страница 222: ...Somat eDAQlite 222 I2773 4 4 en HBM public ...
Страница 224: ...Somat eDAQlite 224 I2773 4 4 en HBM public ...
Страница 227: ...I2773 4 4 en 227 Somat eDAQlite HBM public ...