Somat eDAQ
lite
72
I2773-4.
4
en
4.5
Viewing Channel Displays
TCE includes a variety of integrated run-time displays to view real-time data from input
channels and computed channels during a test run. TCE also offers a several signal
display types to view transducer input signals when a test run is not in progress.
Category
Indicator
Description
Test Run Status
Test Initialized
Indicates that a test is initialized on the eDAQ
lite
.
Remote Control
If a test is initialized, indicates the status of the remote control mode as
either disabled, enabled or suspended.
Run #
If a test is initialized, indicates the current run number or the next run
number if no test is running.
Run or Preview Started
Indicates that a test run or preview is in progress.
Run Time
If a test run or preview is in progress, indicates the elapsed time since the
start of the run. The elapsed time display rolls over after 1000 hours.
Post Run Tasks
Indicates that a test run is stopped, but the required post run tasks are not
completed.
RAM Disk Files
Origin
Indicates the original TCE name of the current test setup file.
Setup
Indicates the eDAQ
lite
reference name of the current test setup file.
Data
Indicates the name of the current SIF data file. Note that even when using
only SIE data, the eDAQ
lite
retains a very small RAM disk-based SIF file
for internal purposes.
RAM Disk Memory
(in bytes and percent total of
RAM disk memory)
Total
Indicates the total RAM disk memory on the eDAQ
lite
.
SIF File
Indicates the current size of the resident SIF data file.
Unused
Indicates the unused memory available for data file storage.
PC Card Disk Memory
(in bytes and percent of total
PC Card memory)
Total
Indicates the total memory on the PC Card.
SIE File
Indicates the cumulative size of the SIE data files currently on the PC
Card.
SIF File
Indicates the cumulative size of the SIF component data files current on
the PC Card.
Unused
Indicates the unused memory on the PC Card available for data file
storage.
SIF File limited to
Indicates the maximum allowable size for the SIF file.
SIF File Built on PC Card
If PC Card data storage is in use, indicates that the SIF file has been
consolidated and the PC Card can be removed from the eDAQ
lite
after
powering down.
HBM: public
Содержание eDAQlite
Страница 1: ...User Manual English Deutsch Espanol I2773 4 4 en HBM public Somat eDAQlite with TCE Software ...
Страница 2: ...Somat eDAQlite 2 I2773 4 4 en HBM public ...
Страница 16: ...Somat eDAQlite 16 I2773 4 4 en HBM public ...
Страница 22: ...Somat eDAQlite 22 I2773 4 4 en HBM public ...
Страница 88: ...Somat eDAQlite 88 I2773 4 4 en HBM public ...
Страница 106: ...Somat eDAQlite 106 I2773 4 4 en HBM public ...
Страница 128: ...Somat eDAQlite 128 I2773 4 4 en HBM public ...
Страница 190: ...Somat eDAQlite 190 I2773 4 4 en HBM public ...
Страница 202: ...Somat eDAQlite 202 I2773 4 4 en HBM public ...
Страница 222: ...Somat eDAQlite 222 I2773 4 4 en HBM public ...
Страница 224: ...Somat eDAQlite 224 I2773 4 4 en HBM public ...
Страница 227: ...I2773 4 4 en 227 Somat eDAQlite HBM public ...