Somat eDAQ
lite
62
I2773-4.
4
en
Copying Channels and DataModes
When creating many channels or DataModes with similar properties, use the Copy
option available in each window. For computed channels and DataModes, TCE only
allows the creation of one copy at a time.
For transducers, TCE allows the creation of multiple copies. The number of copies
defaults to the maximum allowed. TCE automatically assigns a connector to each a
new channel. Choose the default IDs mode as detailed below.
Modifying Channels and DataModes
To modify the parameters of an existing channel or DataMode, highlight the desired
definitions and select Edit or double click the definition entry. For computed channels
and DataModes, TCE limits the edit operation to one definition at a time.
For transducers, TCE allows group edits for a set of channels of the same type. After
selecting edit, choose which set of parameters to modify. The available parameters
vary depending on the type of channel.
Deleting Channels and DataModes
Delete a single definition or a set of definitions by simply highlighting the desired
channels or DataModes and selecting Del. Note that any computed channel or
DataMode that uses a deleted channel as an input remains listed but is no longer a
valid definition.
4.1.4
Using Existing Setup Definitions
TCE provides several methods for using the setup information from existing setup and
data files. These include simply opening and modifying a previously saved test setup,
extracting setup and supporting files from a SIE or SIF data file and importing defined
network nodes.
Modifying an Existing Test
Opening and modifying an existing test setup file is probably the most common mode
of defining test after creating an initial test from scratch. To open a previously saved
file, select Open Setup from the File menu or toolbar. Modify the setup as desired
using the same methods described for creating a file. To save the setup to a different
file, select Save Setup As from the File menu.
To support setup files generated outside of the TCE software, TCE validates the setup
file fields on every open setup command. Specifically, TCE validates all fields
associated with the DataMode, computed channel, transducer channel and test ID
modules. The hardware modules are not validated under the assumption that they will
be updated using a hardware query. TCE generates a log file in the TCE working
directory that contains a list of warnings and errors found during validation.
Default IDs Mode
Description
All Fields Blanked
Create the copies with blank ID names. Manually enter the ID names
in the next window.
All Fields Same as
Original
Create the copies with ID names identical to the original channel. Edit
the ID names in the next window such that there are no duplicates.
Numeric Increment
(Suffix)
Create the copies with an increasing numeric suffix in the ID name. If
desired, edit the ID names in the next window.
HBM: public
Содержание eDAQlite
Страница 1: ...User Manual English Deutsch Espanol I2773 4 4 en HBM public Somat eDAQlite with TCE Software ...
Страница 2: ...Somat eDAQlite 2 I2773 4 4 en HBM public ...
Страница 16: ...Somat eDAQlite 16 I2773 4 4 en HBM public ...
Страница 22: ...Somat eDAQlite 22 I2773 4 4 en HBM public ...
Страница 88: ...Somat eDAQlite 88 I2773 4 4 en HBM public ...
Страница 106: ...Somat eDAQlite 106 I2773 4 4 en HBM public ...
Страница 128: ...Somat eDAQlite 128 I2773 4 4 en HBM public ...
Страница 190: ...Somat eDAQlite 190 I2773 4 4 en HBM public ...
Страница 202: ...Somat eDAQlite 202 I2773 4 4 en HBM public ...
Страница 222: ...Somat eDAQlite 222 I2773 4 4 en HBM public ...
Страница 224: ...Somat eDAQlite 224 I2773 4 4 en HBM public ...
Страница 227: ...I2773 4 4 en 227 Somat eDAQlite HBM public ...