I2773-4.
4
en
101
Somat eDAQ
lite
5.10
SMART Modules
SMART module adapters act as an interface between a transducer and an ELHLS
input channel which powers the module. Each SMART module provides specialized
signal conditioning as a front end to the ELHLS signal conditioning and includes
independent self-identification capabilities and self-calibration parameters. The
following table lists the available SMART modules.
For more information on setting up SMART module input channels, see
Module Input Channels” on page 118
. For information on wiring SMSTRB4 inputs, see
“SMSTRB4 (Strain SMART Module)” on page 205
Installation
The eDAQ
lite
does not sense when a SMART module is installed or removed. After
connecting a module, either cycle the eDAQ
lite
power or perform a hardware query
to detect the installed SMART module. In both of these cases, the eDAQ
lite
applies
power and sends a query to all ELHLS channels that support SMART modules. Note
that the SMART modules remain in a default configuration until an action such as
starting a DVM display, performing a calibration or initializing a test. This also means
that a configured SMART Module that is removed and reinstalled reverts to an
unconfigured state until one of these same actions.
Flash Memory
All SMART modules have three logical segments of flash memory. Two are reserved
for factory use; one to store the microprocessor execution code and the other to store
serial number and factory calibration parameters. The third area is the user data
segment broken into two logical partitions.
1. The first partition holds TCE parameters that can completely configure the TCE
transducer channel setup when the SMART module is installed. If no information
exists in this partition, TCE sets up the transducer channel in a default mode when
the module is added.
2. The second partition is designed for pass-through information not used by TCE.
Add any desired information such as physical locations of transducers or
associated vehicle or system indentifications. All pass-through keywords must start
with the prefix “UI_” (“UI” followed by the underscore character).
SMART Module
Order Number
Description
SMSTRB4 Strain
SMART Module
1-SMSTRB4-120-2 or
1-SMSTRB4-350-2
The SMSTRB4 supports full-, half- and
quarter- bridge transducers and includes 5-
and 10-volt excitation options and internal
shunt calibration using either 50- or
100-kilohm shunt resistors with both upscale
and downscale shunting options.
SMITC
Thermocouple
SMART Module
1-SMITC-2
The SMITC supports fully-isolated
thermocouples of type J, K, T or E over the full
temperature range of the thermocouple.
HBM: public
Содержание eDAQlite
Страница 1: ...User Manual English Deutsch Espanol I2773 4 4 en HBM public Somat eDAQlite with TCE Software ...
Страница 2: ...Somat eDAQlite 2 I2773 4 4 en HBM public ...
Страница 16: ...Somat eDAQlite 16 I2773 4 4 en HBM public ...
Страница 22: ...Somat eDAQlite 22 I2773 4 4 en HBM public ...
Страница 88: ...Somat eDAQlite 88 I2773 4 4 en HBM public ...
Страница 106: ...Somat eDAQlite 106 I2773 4 4 en HBM public ...
Страница 128: ...Somat eDAQlite 128 I2773 4 4 en HBM public ...
Страница 190: ...Somat eDAQlite 190 I2773 4 4 en HBM public ...
Страница 202: ...Somat eDAQlite 202 I2773 4 4 en HBM public ...
Страница 222: ...Somat eDAQlite 222 I2773 4 4 en HBM public ...
Страница 224: ...Somat eDAQlite 224 I2773 4 4 en HBM public ...
Страница 227: ...I2773 4 4 en 227 Somat eDAQlite HBM public ...