16. Changing the Settings
You can change settings such as the measuring mode and the number
of decimals in displayed data.
When you select "Config." in menu mode, the two-page configuration
menu is displayed.
16.1 Measuring Mode
You can select any of the following measuring modes.
Page 1
* Single:
The instrument automatically terminates fine
measurement after taking one reading.
Average: Displays the average value calculated from the
number of times fine measurement is repeated.
(Repeat default setting: 5 times, Repeat setting
range: 2 to 9 times.)
Page 1
•
Meas. (measuring mode)
•
Display (fractional/decimal
representation of height units)
•
Adjust (checks and adjustment)
•
RS-232C (communication
parameters)
Page 2
•
Auto-off (auto power-off)
•
Unit (unit of measurement)
• Press
to toggle between the pages.
• Asterisks (*) indicate factory settings.
• Settings are kept in memory after power-off.
• "19.2 Adjusting the Reticle" for the check and adjustment
procedure.
Notes: