20
Pr
el
im
in
ar
ie
s
6.
Focusing and Sighting
•
Before using the instrument
Turn the eyepiece to adjust the eyepiece image.
1 Using the gunsight, aim the objective lens toward the staff.
2 Gradually turn the eyepiece outward, stopping just before the
reticle cross-lines become blurred.
3 Turn the horizontal fine motion knobs until the staff is nearly
centered in the field of view, then turn the focusing knob to focus on
the staff.
4 Looking through the telescope, shift your eyes slightly up and down
and to each side.
5 If the staff and reticle show no deviation, the instrument is ready for
use.
If the staff and reticle deviate, return to step 2.
Procedure
• If deviation occurs at step 5, errors will occur when taking
measurements. Always make sure the instrument is correctly
focused.
Important:
Содержание SDL30
Страница 76: ...75 Other Procedures RAB code RAndom Bi directional code is a coded staff used with SOKKIA digital levels ...
Страница 82: ...81 Regulations For users in the Republic of Korea ...
Страница 83: ...82 MEMO ...
Страница 84: ...83 MEMO ...
Страница 85: ...84 MEMO ...
Страница 86: ...This is the mark of the Japan Surveying Instruments Manufacturers Association Li ion S Li ion ...
Страница 87: ...SURVEYING INSTRUMENTS OPERATOR S MANUAL SDL30 SDL50 Digital Level 13th ed 16 1003 2000 SOKKIA TOPCON CO LTD ...