86
-
Point table
No.1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
6ms or more
Servo-on (SON)
Ready (RD)
Trouble (ALM)
Automatic/manual
selection (MD0)
In-position (INP)
Rough match (CPO)
Point table No.
Servo motor
speed
Forward
rotation
Reverse
rotation
0r/min
ON
OFF
Forward rotation start
(ST1)
1
ON
OFF
(Note 2)
Travel completion
(MEND)
Point table No. output
(PT0 to PT2)
3ms or less
Point table
No.2
Point table
No.3
1
(Note 1)
6ms or
more
ON
OFF
ON
OFF
ON
OFF
Forward rotation
stroke end
(LSP)
Reverse rotation
stroke end
(LSN)
Forced stop