-
92
-
No.
3-digit,
7-segment
LED
display
Name
The servo motor stops
/does not stop.
W
a
rn
in
g
A.90
Home positioning incomplete warning
Stops
A.91
Driver overheat warning
Does not stop
A.96
Home position setting error
Stops
A.97
Program operation disabled
Does not stop
A.98
Software limit warning
Stops (Note 2)
A.99
Stroke limit warning
Stops (Note 2)
A.E0
Excessive regeneration warning
Does not stop
A.E1
Overload warning 1
Does not stop
A.E6
Servo forced stop warning
Stops
A.E9
Main circuit off warning
Stops
A.EC
Overload warning 2
Does not stop
A.ED
Output watt excess warning
Does not stop
A.F0
Tough drive warning
Does not stop
Note 1. Deactivate the alarm about 30 minutes of cooling time after removing the cause of occurrence.
2. Operation to the direction which cancels the warning can be performed.