77
-
5.12
Display
All Monitor List
The method how to obtain the electric actuator condition is described with the display all function of the setup software.
①
Click
“Monitor” - “Display All” of the setup software to display “Display All” window.
②
The condition of each item is displayed.
For off line of the setup software, [----] will be displayed.
The following items are displayed for LECSA.
No.
Name
Function
Indication
range
Unit
1
Cumulative
feedback pulses
Feedback pulses from the servo motor encoder are
counted and displayed.
When exceed 999999999, it returns to zero.
Press the [Clear] button to reset the display value to 0
(zero).
Reverse rotation is indicated by a minus (-) sign.
-999999999
to 999999999
pulse
2
Servo motor speed
The servo motor speed is displayed.
The value rounded off is displayed in 0.1r/min.
Reverse rotation is indicated by a minus (-) sign.
-5400
to
5400
r/min
3
Droop pulses
The number of droop pulses in the deviation counter is
displayed.
Reverse rotation is indicated by a minus (-) sign.
-999999999 to
999999999
pulse
4
Cumulative
command pulses
The position command input pulses are counted and
displayed.
Press the [Clear] button to reset the display value to
zero.
Reverse rotation is indicated by a minus (-) sign.
-999999999 to
999999999
pulse
①