26
-
5.3.4 Recommended Parameter Values by Actuator Model
Please change the parameter values according to the customer application. See section 4 of the
“LECSA Operation
Manual” for details.
Recommended Parameter Values [LEF]
Series
LEFS25
LEFS32
LEFS40
Lead symbol
H
A
B
H
A
B
H
A
B
Lead
20
12
6
24
16
8
30
20
10
Parameter *1,*2
Para
No
Initial
value
Recommended Value
Number of command input
pulses per revolution *3.
PA05
100
100
Electronic gear numerator *3.
PA06
1
100 (Positioning mode: 10)
Electronic gear denominator *3.
PA07
1
20
12
6
24
16
8
30
20
10
Feel length multiplication (STM)
(Multiplier)
PE02
0000
0000 ((<1000 stroke)/0001 (>1000 stroke)
Home position return type
PE03
0010
□□□
3 (Stopper type)
Home position return direction
PE03
0010
□□
1
□
(Motor side)
Home position return Speed
(rpm)
PE04
500
90
150
300
75
113
225
60
90
180
Home position return/JOG
operation
Accelerationeration/Deceleration
time constants (msec)
PE07
100
1000
600
300
1200
800
400
1500
1000
500
Home position return position
data (μm)
PE08
0
-2000 (<1000 stroke)/-200 (>1000 stroke)
Stopper type home position return
stopper time (msec)
PE10
100
200
Stopper type home position
return torque limit value (%)
PE11
15
30
Regenerative option
PA02
000
000 (Non)/002 (LEC-MR-RB-032)
Rotation direction selection *4
PA14
0
1 (+
:
Counter motors side)
Adaptive tuning mode
PB01
000
000
Load to motor inertia moment
ratio
PB06
7
7
Machine resonance
suppression filter 1
PB13
4500
4500
Notch shape selection 1
PB14
000
000
Differs to initial value
*1. Parameter is set to the recommended value. Please set parameter according to customer application.
*2. Mechanical resonance may occur depending on the shape or mounting orientation of the work piece. Please change
this parameter during initial configuration.
(Parameter initial configuration
⇒
Set the recommended parameter value
⇒
Operation start)
*3. Other than positioning mode: Actuator travel distance at 10 [μm/pulse] per pulse.
Positioning Mode: Minimum actuator travel distance of 1[μm].
*4. When the motor mounting position is right side parallel (LEFS*R) or left side parallel (LEFS*L), the rotation
direction selection is 0(+: Counter motors side).