- 76 -
No.JXC
※
-OMT0007-D
18.5 Maintenance Precautions
Warning
(1) Do not disassemble or repair the product.
Fire or electric shock can result.
(2) Before modifying or checking the wiring, the voltage should be checked with a tester 5
minutes after the power supply is turned OFF.
Electric shock can result.
Caution
(1) Maintenance should be performed according to the procedure indicated in the Operating
Manual.
Incorrect handling can cause injury, damage or malfunction of equipment and machinery.
(2) Removal of product
When equipment is serviced, first confirm that measures are in place to prevent dropping of work
pieces and run-away of equipment, etc, then cut the power supply to the system. When machinery is
restarted, check that operation is normal with actuators in the proper positions.
[Lubrication]
Caution
(1) The product has been lubricated for life at the manufacturer's and does not require lubrication
in service.
Contact SMC if lubrication is to be applied.
18.6 Precautions for actuator with lock
Warning
(1) Do not use the lock as a safety lock or a control that requires a locking force.
The lock used for the product with a lock is designed to prevent dropping of work pieces.
(2) For vertical mounting, use the product with a lock.
If the product is not equipped with a lock, the product will move and drop the work piece when the
power is removed. If the actuator with lock is not used, preventive measures should be taken in the
design of the equipment.
(3) "Measures against drops" means preventing a work piece from dropping due to its weight
when the product operation is stopped and the power supply is turned OFF.
(4) Do not apply an impact load or strong vibration while the lock is activated.
If an external impact load or strong vibration is applied to the product, the lock will lose its holding
force and damage to the sliding part of the lock or reduced lifetime can result. The same situations
will happen when the lock slips due to a force over the thrust of the product, as this accelerates the
wear to the lock.
(5) Do not apply liquid or oil and grease to the lock or its surrounding.
If liquid or oil and grease is applied to the sliding part of the lock, its holding force will reduce
significantly.
(6) Take measures against drops and check that safety is assured before mounting, adjustment
and inspection of the product.
If the lock is released with the product mounted vertically, a work piece can drop due to its weight.
(7) When the actuator is operated manually (when
“SVRE” signal is OFF), supply 24VDC to the
[LK RLS] terminal of the power supply connector.
If the product is operated without releasing the lock, wear of the lock sliding surface will be
accelerated, causing a reduction in the holding force and the life of the locking mechanism.
(8) Do not supply 24VDC power supply constantly to the [LK RLS].
Only supply 24VDC power supply to the [LK RLS(Lock release)] terminal during normal operation. If
power is supplied to the [LK RLS] terminal continuously, the lock will be released, and workpieces
may be dropped at stop (EMG).
/For details of wiring please refer to the operation manual for the controller (JXC series).