The table below shows the changes in the signal with respect to the state of the controller.
BUSY
INP
SVRE
Lock
SETON OUT0 to 5
During sto
pping when “SVON” is OFF after
turning ON the power supply to the controller
OFF
OFF
OFF
Lock
OFF
OFF
During stopping when “SVON” is ON after
turning ON the power supply to the controller
OFF
OFF
ON
Unlock
OFF
OFF
During returning to origin
ON
OFF
ON
Unlock
OFF
OFF
The actuator is at the origin. On completion of
“SETUP”
OFF
ON(
2)
ON
Unlock
ON
OFF
During movement by positioning/pushing
operation
ON
OFF
ON
Unlock
ON
ON(
3)
The actuator is paused by “HOLD”
OFF
OFF
ON
Unlock
ON
ON(
3)
On completion of the positioning operation
OFF
ON(
5)
ON
Unlock
ON
ON(
3)
Stopped due to pushing a workload in
pushing operation
OFF
ON
ON
Unlock
ON
ON(
3)
Stopped due to no detection of workload
during a pushing operation
OFF
OFF
ON
Unlock
ON
OFF
During stopping when “SVON” is OFF after
returning to the home position
OFF
OFF (
5)
OFF
Lock
ON
ON(
4)
EMG signal stop from the PWR connector
when the actuator is at the origin
OFF
OFF (
5)
OFF
Lock
ON
OFF
2 The signal turns ON when the actuator is within the range defined in the basic parameter setup.
3 The signal is updated on the transition of (ON
→ OFF) of the DRIVE signal.
4 Retains the previous state.
5 The signal turns ON when the actuator is "In position" according to the step data.
●
Byte 2, 3: Controller information flag
Byte
Bit
Signal name
Description
2
0-3
(Unused)
-
4
READY
READY turns ON when Servo is ON and no alarm is
generated. The READY flag turns ON.
5
ALARM flag
Alarm generated when problems occur to the internal
process of JXCD1 or the communication with PLC.
OFF during normal condition. ON when alarm is generated.
6-7
(Unused)
-
3
0-7
(Unused)
-
●
Byte 4-19
The memory contents of Byte 4-35 differ depending on the set content of
Input data length of IO data
length.
The memory contents of Byte 4-35 depending on
Input data length of IO data length
are shown below.
And, refer to
4.3 DeviceNet object (2) IO object (Class: 68 h) (P.
for the setting of IO data length.
[Output data length: When
4 Bytes
is selected]
●
Byte 4-19: Not available
[Output data length: When
10 Bytes
is selected]
●
Byte 4-7: Current position
Byte
Signal name
Description
4
Current position
Current position of the actuator is shown in multiples of 0.01mm
when numerical data can be read. (
6)
E.g.) 800.00 [mm] (80000d=13880h) is output
“4Byte” = 80h
“5Byte” = 38h
“6Byte” = 01h
“7Byte” = 00h