5.2 Flow Chart of Operation Screen
5-3
5.2.2
Flow Chart of Operation Screen (2)
Figure 5-3 Flow Chart of Operation Screen (2)
Table 5-2 Descriptions of Operation Screens (2)
Screen
Descriptions
Reference
Display Setting screen 1
Allows the changing of the language for messages that are displayed on the
operation touch panel and the units of flow rate and pressure.
Page 5-24
Display Setting screen 2
Allows time setting for this product.
Page 5-25
Communication Setting screen Allows detail setting for communication specifications.
Page 5-27
Serial Communication Setting
screen
Allows detail setting for serial communication specifications.
Page 5-28
CH1(2)DIO Communication
Setting screen
Allows detail setting for DIO (analog) communication specifications.
Page 5-32
Control Setting screen
Allows access to the CH1 and CH2 Control Setting screens.
Page 5-44
CH1(2) Control Setting screen
Allows the setting of compressor and pump ECO limits, offset, and circulating
fluid outlet pressure upper limit.
Page 5-44
Maintenance screen
Allows access to the electron expansion valve adjustment screen. Not
allowed to use during normal operation.
Page 5-49
Auto Tuning screen
Allows auto tuning of the electron expansion valve. Not allowed to use during
normal operation.
Page 5-50
EV Opening Setting screen
Allows opening adjustment of the electron expansion valve. Not allowed to
use during normal operation.
Page 5-51
Purge Mode screen
Allows the use of the circulating fluid automatic collection function (optional).
Page 5-52
Display Setting screen 1
Detail Setting screen 2
Purge Mode screen
Main screen
Communication Setting screen
Control Setting screen
Maintenance screen
CH1 Control Setting screen
Serial Communication
Setting screen 1
DIO Communication
Setting screen 1
Auto Tuning screen
EV Opening Setting screen
Detail Setting screen 1
Display Setting screen 2
* The Detail Setting screen 2 and Purge
mode screen are only available in the
product equipped with the Automatic
circulating fluid collector (optional).
Содержание HRZD020-W1S-W1S
Страница 24: ...HRX OM M005 Chapter 2 Name of Each Section 2 1 Name of Each Section HRZD Series 2 2 ...
Страница 44: ...HRX OM M005 Chapter 4 Product Startup and Shutdown 4 5 Product Startup and Shutdown HRZD Series 4 6 ...
Страница 98: ...HRX OM M005 Chapter 5 Product Operation 5 3 Operation Screen HRZD Series 5 54 ...
Страница 128: ...HRX OM M005 Chapter 8 Appendix 8 8 Thermo Chiller Daily Inspection Sheet HRZD Series 8 20 ...