Specification for fluorinated fluid (wide temperature) double inverter
(HRZD020-WS-WS)
Table 8-1 Specification for fluorinated fluid (wide temperature) double inverter (HRZD020-WS-WS)
Model
HRZD020-WS-WS
Channel
1
2
Cooling method
Water cooled refrigerant type
Temperature control system
PID control
PID control
Cooling capacity
*1
kW
9.5 (Circulating fluid at 20°C)
9.5 (Circulating fluid at 20°C)
Operating temperature range
°C
-30 to 90
-30 to 90
Temperature stability
°C
±0.1
*2
±0.1
*2
Circulating fluid flow display
range
*3
L/min
5 to 40
5 to 40
Circulating fluid flow setting
range*
4
L/min
10 to 40
10 to 40
Circulating fluid discharge
pressure display range
MPa
0 to 1.5
0 to 1.5
-30 to 40°C: Galden
®
HT135
*5
Fluorinert
TM
FC-3283
*5
20 to 90°C: Galden
®
HT200
*5
Fluorinert
TM
FC-40
*5
Circulating fluid
(No intrusion of foreign body)
Refrigerant
R404A (HFC), (GWP: 3784)
R404A (HFC), (GWP: 3784)
Pump capacity
*6
MPa
0.72 (At 20L/min)
Inverter-driven flow control function
applied
0.72 (At 20L/min)
Inverter-driven flow control function
applied
Main Tank capacity
*7
L Approx.15
Approx.15
Sub Tank capacity
*8
L Approx.16
Approx.16
Circulating fluid port (supply/return)
Rc 3/4
Rc 3/4
Facility water
°C / MPa
10 to 35 / 0.3 to 0.7
Required flow of facility water
*9
L/min
15 (Facility water at 25°C)
15 (Facility water at 25°C)
Facility water port (inlet/outlet)
Rc 1/2
(single system for channels 1,2)
Power supply
3-phase 50/60Hz AC200/200 to 208V±10%
Rated flow
*10
L/min
20
20
Max. operating current
A
52
Main breaker size
A
60
Temperature fuse operating
temperature
°C 98
98
Dimensions
*11
mm
W600
×
D845
×
H1525
Weight
*12
kg
380
Communication
Serial RS-232C/485 (Dsub-9pin), Contact signal / Analog (Dsub-25pin)
Materials of circulating fluid wetted parts
SUS, EPDM, copper brazing (heat exchanger ), PPS, silicone, fluoroplastics
Maximum height difference between
the unit and the external
equipment
*13
m
Max. 10
Max. 10
*1: The capacity is derived under the conditions that the facility water temp. is 25°C and that the circulating fluid flows at 20L/min, if
the heat source is direct-coupled to the circulating fluid circuit of the product. Available cooling capacity decreases with increase
in the length of piping to the customer system, causing an endothermic reaction.
*2: The discharge temperature (this system) is derived under the conditions that the rated flow of the circulating fluid is obtained and
that the circulating fluid supply is direct-coupled to the circulating fluid return. The installation environment, power supply, and
facility water must be in the working range and stable.
*3: The valve must be fully opened to use when connected to the circulating fluid supply.
*4: Circulating fluid flow control may be disabled with respect to the set values, depending on piping specifications on your system.
*5: Galden
®
is a registered trademark of Solvay Solexis, and Fluorinert
TM
is a trademark of U.S. 3M.
*6: The capacity is derived at the Outlet of this system when the circulating fluid temp. is at 20°C.
*7: This is a minimum amount of the fluid for operation of the Thermo Chiller outfitted with internal piping and heat exchanger in this
system. Circulating fluid temp.: 20°C
*8: This is an auxiliary space with a main tank capacity excluded. The level of the fluid in external piping must be under a sub tank
capacity.
*9: This value will be needed to when temperature will be going down. If the product is under no or light load, it is operational at
Содержание HRZD020-W1S-W1S
Страница 24: ...HRX OM M005 Chapter 2 Name of Each Section 2 1 Name of Each Section HRZD Series 2 2 ...
Страница 44: ...HRX OM M005 Chapter 4 Product Startup and Shutdown 4 5 Product Startup and Shutdown HRZD Series 4 6 ...
Страница 98: ...HRX OM M005 Chapter 5 Product Operation 5 3 Operation Screen HRZD Series 5 54 ...
Страница 128: ...HRX OM M005 Chapter 8 Appendix 8 8 Thermo Chiller Daily Inspection Sheet HRZD Series 8 20 ...