Fig. 15
Filter unit
To ill and subsequently vent the previ-
ously replaced ilter element/ilter body,
raise the change-over lever until bubble-
free lubricating oil discharges from the
already opened vent plug.
Raise the change-over lever (
1
) until
bubble-free lubricating oil discharges
from the vent plug (
5
or
6
).
Tighten the vent plug (
5
or
6
).
If necessary, slowly raise the change-over
lever (
1
) and turn it 120° until it snaps,
then lower the change-over lever(
1
).
Perform a leak test.
Unactuated
Raised
(actuated)
Change-over lever (1)