Cable layout and connections
69
851-164336 / D
Figure 24
Connections to
the Motor Control Unit
C19
C17
REMOTE
S 302
HOIST STOP
LOWER
HAND CRANK
S 303
(CD5821)
Cable
strip
E301
S302
Hand
crank
(S303)
S301
C15 - Sonar Interface Unit
This is the control and data cable from the Sonar Interface Unit in
the wheelhouse to the Transceiver Unit in the sonar room. The
cable is included in the standard delivery, with a length of 100
meters, and has a pre-connected plug in the wheelhouse end.
Note
Cable C17 from the Transceiver Unit to the Motor Control Unit
must be connected before cable C15. This is necessary because
cable C17 is connected to the bottom row of terminal E201.