9.4 Starting up the Hull Unit
Introduction
Observe the following procedure to start up the Hull Unit. To
ensure correct performance, tick off every item when the action has
been carried out.
WARNING
Before starting up the sonar equipment on a
recently launched vessel, make sure the depth
under the keel is sufficient for the transducer to
be lowered safely.
When starting up the equipment on board a
vessel in dry dock, check first under the vessel
and inside the sonar room. Personnel, tools and
other potential obstructions must be kept clear
of the transducer and related lowering and
hoisting machinery to avoid personal injury or
damage to the equipment.
Functional check
Before you start the functional check, make sure that the mains
fuses for the hull unit has been disconnected in the fuse box. This
check will only require the +24 Vdc standby power from the
Transceiver Unit.
1
Use a spanner to open the door on the Motor Control Unit.
- The unit is mounted on the Hull Unit.
2
Press the red button marked
0
on the motor overload switch
S301
in the Motor Control Unit.
→
Refer to figure 31 on page 93.
3
Check that the hoisting/lowering switch
S302
in the Motor
Control Unit is set in the
Stop
position.
4
Locate the hand crank in the Motor Control Unit, and mount
the crank onto the shaft.
5
Locate the brake release screw on the motor (not on SP75!),
and use an 4 mm Allen key to tighten up the screw until the
motor brake is mechanically released (approximately 2 - 3
turns clock- wise).
6
Turn the hand crank counter-clockwise to lower the
transducer manually approximately 10 cm (4”).
Содержание Simrad SP70
Страница 2: ......
Страница 14: ...Simrad SP70 X 851 164336 D This page is intentionally left blank...
Страница 62: ...Simrad SP70 46 851 164336 D Figure 13 Mounting the Transceiver Unit CD3110A...
Страница 226: ...Simrad SP70 210 851 164336 D Party Date Signature Party Date Signature Party Date Signature...
Страница 227: ......
Страница 229: ......