Cable layout and connections
65
851-164336 / D
→
Figure 21 shows the connection to the Operating Panel.
→
The figure on page 62 shows the connection to the Sonar
Processing Unit.
→
Cable details on page 190.
Observe the following procedure for the connection of the USB
data cable.
1
Connect the quadratic USB connector to the Operating
Panel.
2
Connect the rectangular USB connector to the lowest USB
connector on the rear left hand side of the Sonar Processor
Unit.
Figure 21 Connections to
the rear side of the
Operating Panel
C8 / C9
C7
(CD5718)
USB-A
USB-B
C8 / C9 - Operating panel (Power and serial)
This is a special dual cable from the Operating Panel to the Sonar
Processor Unit and the Sonar Interface Unit.
This dual cable has a common 15-pin Delta connector in the
Operating Panel end, a 9-pin female Delta connector in the Sonar
Processor Unit end (cable C8), and a 9-pin male Delta connector
in the Sonar Interface Unit end (cable C9).
The cable is included in the standard delivery, and the cable length
is 4,5 meter.
→
Figure 21 shows the connections to the Operating Panel.
→
Cable details on page 191.
Observe the following procedure for the connection of the panel
cable.
1
Connect the 15-pin Delta connector to the Operating Panel.
2
Connect the 9-pin female Delta connector to the
Serial A
connector on the rear side of the Sonar Processor Unit.
3
Connect the 9-pin male Delta connector to the
J4
connector
in the Sonar Interface Panel.
Содержание Simrad SP70
Страница 2: ......
Страница 14: ...Simrad SP70 X 851 164336 D This page is intentionally left blank...
Страница 62: ...Simrad SP70 46 851 164336 D Figure 13 Mounting the Transceiver Unit CD3110A...
Страница 226: ...Simrad SP70 210 851 164336 D Party Date Signature Party Date Signature Party Date Signature...
Страница 227: ......
Страница 229: ......