Actions on the bridge
Note
This procedure must be performed simultanously with the next
procedure;
Actions in the sonar room
.
The instructions marked
Sonar room
are performed in the sonar
room.
1
Start up the sonar.
2
Check that the depth is sufficient for lowering of the
transducer.
3
Lower the transducer to middle position by giving a short
press on the
Middle
button.
4
Set the
TX Power
in the
Horizontal
menu to
Low
, and
check that echoes appear on the display.
5
Sonar room:
Check that the voltmeter on the HV Power unit
shows approximately 25 V.
6
Sonar room:
Check that the
TX Enable
LED (TXEN) on
the TIB board starts flashing.
→
For location of the TXEN LED, refer to figure 39 on page
117.
7
Set the
TX Power
in the main menu to
Medium
, and check
that the echoes become stronger.
8
Sonar room:
Check that the voltmeter on the HV Power unit
shows approximately 50 V.
9
Set the
TX Power
in the
Horizontal
menu to
Full
, and check
that the echoes become even stronger.
10
Sonar room:
Check that the voltmeter on the HV Power unit
shows approximately 105 V.
If the Hull Unit is installed differently from the recommended
orientation, the echo picture on the display must be aligned to show
the echoes in correct position.
→
Refer to
Alignment of the sonar picture
on page 121.
Содержание Simrad SP70
Страница 2: ......
Страница 14: ...Simrad SP70 X 851 164336 D This page is intentionally left blank...
Страница 62: ...Simrad SP70 46 851 164336 D Figure 13 Mounting the Transceiver Unit CD3110A...
Страница 226: ...Simrad SP70 210 851 164336 D Party Date Signature Party Date Signature Party Date Signature...
Страница 227: ......
Страница 229: ......