Simrad SP70
112
851-164336 / D
Checking the sonar room functions
Note
This procedure must be performed simultanously with the
procedure and checklist in the previous chapter;
Checking the
bridge functions
.
The instructions marked
Bridge:
are performed on the bridge.
Note that these procedures are more detailed that what is presented
here.
1
Check that the depth under the keel is sufficient to safely
lower the transducer.
2
Bridge:
Start the sonar.
3
Press the black button marked
1
on the motor overload
switch
S301
in the Motor Control Unit.
4
Set the hoist / lower switch
S302
in the Motor Control Unit
to
Remote.
a
Notify the bridge to perform the next step.
5
Bridge:
Lower the transducer to its middle position.
6
Bridge:
Lower the transducer to is lower position.
7
Bridge:
Hoist the transducer to its middle position.
8
Bridge:
Hoist the transducer to its upper position.
9
Bridge:
Lower the transducer to is lower position.
10
Bridge:
Hoist the transducer to its upper position.
11
Set the hoisting/lowering switch
S302
in the Motor Control
unit to the
Stop
position.
a
Notify the bridge to perform the next step.
12
Bridge:
Switch off the sonar.
Содержание Simrad SP70
Страница 2: ......
Страница 14: ...Simrad SP70 X 851 164336 D This page is intentionally left blank...
Страница 62: ...Simrad SP70 46 851 164336 D Figure 13 Mounting the Transceiver Unit CD3110A...
Страница 226: ...Simrad SP70 210 851 164336 D Party Date Signature Party Date Signature Party Date Signature...
Страница 227: ......
Страница 229: ......