Instruction Manual OilGuard Ex M
10
10241E/2
Action
2.
Connect the cooling water to the feed and
drain.
∅
inner hose = 10 mm
The water flow rate must be at least
1 l/min! Max. pressure = 500 kPa (5 bar)
A= feed below
B= drain above
3.
Open the cooling water supply.
3.2
Electrical connections
Auxiliary electrical components such as the data logger must not be installed
and operated in explosion hazardous areas.
Consult the EEx-p system documentation before connecting. Further, the
following basic principles must be observed:
It is imperative that the protective conductor is connected.
Because the unit has no mains switch, a suitable disconnector (switch,
plug) should be installed near the mains connection .
If faults cannot be remedied, the unit must be put out of operation and
protected against inadvertent operation.