After transportation
Check the device and the packaging and transportation material for
damages caused by transportation! Never put a device into operation if
there are visible or hidden transportation damages!
Attention:
After transportation, all electrical connections accessible by the customer
must be checked! Vibrations during transportation may loosen the screws
of clamps.
Check mains wiring and output connections as well as control cables.
Loose cable connections may cause overheating of clamps and cables
and will lead to destruction of the installation.
3.1
Transportation locking devices
Make sure no transportation locking material is left at the device before
putting into operation.
Remove labels and stickers that are not necessary for safe operation.
4
Storage
Aluminum electrolytic capacitors are built into TechnoPlate Power Pack
series and into their control components to ensure correct operation.
These components are subject to natural ageing processes.
Aluminum electrolyte capacitors containing liquid electrolyte age over
time due to the electrolyte slowly drying out, depending on temperature.
As a result, these devices should not be stored for longer than six
months. If you keep replacement devices in storage, they should be
integrated into systems after six months at the latest. If not, they should
be connected to the power supply in non-operational mode for at least an
hour before they are installed and also at least once a year to recondition
the electrolyte capacitors.
Important
Condensate may form on the external surfaces of devices if air humidity
is high.
This condensation may cause the external casing to corrode. It is
therefore recommended to store these devices in a dry and/or air-
conditioned room with adequate ventilation to prevent such corrosion.
Ensure that the ventilation openings are not covered when you mount the
devices. Each device should be left to adjust to room temperature for a
couple of hours after installation before it is put into operation.
4.1
Environmental conditions for storage
Ambient temperature: 0 °C to +50 °C (for storage only)
Air humidity:
15 to 95 %, non-condensing