20.7.1
Configuration of the Overload detection
If you are in the in the “Settings” menu, press the key located beside the
Overload detection
line.
The display shows:
The voltage drop threshold can be set from 1% to 99%.
Use the keys “STORE / STEP RESET to set the value
The recommended value is 20-40%.
Confirm the setting with ENTER.
Function:
If a direct short occurs between the anode and the part:
The display shows:
“OVERLOAD”
and a short “beep” is heard.
The DC output is shut off.
The LED in OFF key is flashing.
The LED in CLR key is flashing.
Press CLR key for alarm reset.
Press the ON key to restart the DC power supply.