TC12 Installation, Commissioning & Maintenance Handbook
666/HE/43100/000
Page 111
Issue 10
Comment:
Displays the lamp supply in volts. If no second lamp supply is
defined KEV will display ‘KEV 1:N/A’.
3.3.3.60 Display LMU Aspect Learn Status (KAS)
KAS (sensor number: 1-23) (aspect pattern number: 0 - 6)<enter>
Comment:
Displays a binary byte containing a set of flags (i.e. bits) indicating
the status of LMU monitoring. There is one set of flags for each
possible aspect pattern of each possible current sensor.
Note: Only those flags for valid aspect patterns of used sensors are generated,
all others are set to zero.
The meaning of each bit is listed below:
Bit 0 - AWAIT_DIM - Aspect not yet appeared in DIM
Set if current dim/bright state is known to be bright and AWAIT_DIM_CHANGE is
set. Cleared when dim/bright state is dim and AWAIT_DIM_CHANGE is clear
Bit 1 - AWAIT_BRIGHT - Aspect not yet appeared in BRIGHT
Set if current dim/bright state is known to be dim and AWAIT_DIM_CHANGE is
set. Cleared when dim/bright state is bright and AWAIT_DIM_CHANGE is clear.
Note: Under certain conditions both AWAIT_DIM and AWAIT_BRIGHT bits can
be set for an aspect. If this occurs neither bit will be cleared until the LMU
has learnt the aspect in both dim and bright states.
Bit 2 - AWAIT_ASPECT - Aspect not yet appeared
Set on LMU initialisation. Cleared when aspect first learnt
Bit 3 - AWAIT_DIM_CHANGE - First dim/bright change assessment enabled
Set on LMU initialisation if dim/bright changeover monitoring is enabled. Cleared
after first dim/bright change assessment for the aspect has been completed
Bit 4 - CONF_LOAD - Aspect being assessed for load change
Set when either the 'rise' or 'fall' load change counter is non-zero. Cleared when
both the 'rise' and 'fall' change counters are zero.
Bit 5 - CONF_DIM - Aspect being assessed for dim/bright change
Set when either the 'dim' or 'bright' load change counter is non-zero. Cleared when
both the 'dim' and 'bright' change counters are zero
Bits 6 and 7 - Not used
3.3.3.61 Display LMU Aspect Learn Status (KML)
KML<enter> [PB392 issue 6 or later]
Comment:
Cycles round all the unlearnt phases and aspects indicating how
complete the learning is as a percentage. If a Dim/Bright change is
required the percentage will stop at 50%. When all the aspects are
learnt in one state (Dim or Bright) and the LMU is waiting for the
first Dim/Bright changeover, the KML indicates ‘Awaiting D/B’.
When the learning is complete, KML displays ‘Complete’. If the
LMU is not enabled (KLE:0), then the KML displays ‘LMU Disabled’.
3.3.3.62 Display
Controller
Dim/Bright State (KDB)
KDB (lamp supply: 0 - 1) <enter>