TC12 Installation, Commissioning & Maintenance Handbook
666/HE/43100/000
Page 110
Issue 10
to identify up to four loops.}
‘Q?’
Input is assigned to Queue Unit ?
‘H?’
Input is assigned to HIOCC Unit ?
‘S?’
Input is assigned to Scoot Unit ?
‘L?’
Input is assigned as a Mains state for sensor ?
3.3.3.53 Display Firmware Identity and Issue state (GIC, KIC)
GIC<enter>
Comment:
Displays Firmware Reference Number and Issue State.
3.3.3.54 Display PLD Variant (GPV, KPV)
GPV<enter>
Comment:
Displays PLD Reference Number and Issue State.
3.3.3.55 Display Reply Data (GRD)
GRD (reply byte number: 0 - 14) <enter>
Comment: Enables the reply data currently being transmitted to the instation to
be displayed in binary format.
Note: GRD 0 displays the first byte of the reply message that is the OTU
address, MT bit etc. The first byte of reply data is accessed using GRD 1.
The display is only valid for the configured number of reply bytes.
3.3.3.56 Display Lamp Monitor ADC readings (KAC)
KAC (sensor number: 1-23) (current/voltage selector: 0-1) <enter>
Comment: Displays the ADC current or voltage readings for configured Lamp
Monitor sensors.
Note: The lamp monitor facility must be enabled for ADC readings to be
available.
3.3.3.57 Display learnt load (KEL)
KEL (sensor number: 1 - 23)(aspect pattern number, 0-6):<enter>[PB392 issue 6
or later]
Comment: Displays the learnt loan in Watts at 240 V, with the associated
phase and colour. If the load is not learnt, the display will indicate
zero.
3.3.3.58 Display actual current (KES)
KES (sensor number: 1-23)<enter>
Comment:
Displays the last current reading in milliamps on the Red or the
associated phase and colour.
3.3.3.59 Display lamp supply voltage (KEV)
KEV (Lamp Supply: 0-1)<enter>