![Siemens TC12 Скачать руководство пользователя страница 116](http://html.mh-extra.com/html/siemens/tc12/tc12_installation-commissioning-and-maintenance-handbook_374544116.webp)
TC12 Installation, Commissioning & Maintenance Handbook
666/HE/43100/000
Page 106
Issue 10
3.3.3.37 Mains states input configuration (KMS) L
KMS {mains state input: 0-2 }{ sensor: 1 - 23 }= Input line number: {0 - 31} (255)
This item defines the digital inputs that provide the mains state(s) for the
associated current sensor. Up to three input line numbers are required depending
on the phase type being monitored (see table below).
The following is a list of the lamp mains state entries required for the different
phase types that the current sensors can monitor. If no mains state is required
enter the default value of 255.
Monitored Phase Type
1st entry
2nd entry
3rd entry
IV GREEN
-
-
IVRLM GREEN
RED -
IP
GREEN
VEH. GREEN
-
PV GREEN
PED.
GREEN
-
PP GREEN
-
-
PPW GREEN
WAIT
-
PS
VEH. GREEN
PED. GREEN
WAIT
IPW GREEN
VEH.
GREEN
WAIT
IPS
VEH. GREEN
PED. GREEN
WAIT
XP1 RED
-
-
XV1 GREEN
-
-
XV2 BALL
-
-
XV3 GREEN
AMBER
-
W4 WAIT
-
-
W6 WAIT
-
-
RS -
-
-
SB SIGN
-
-
ST SIGN
-
-
In addition, for PB392 Firmware:
PP4 GREEN
WAIT
-
PS4
VEH GREEN
PED GREEN
WAIT
IP4
PED GREEN
VEH GREEN
WAIT
IS4
VEH GREEN
PED GREEN
WAIT
Note
The 32 inputs are numbered 1 to 32 in section 3.2.3.5, corresponding to
the associated pin on the 40 way input connector, however the handset
command numbers the inputs from 0 to 31, for the 32 inputs.