Bit No.
Name
Range of Values / Meaning
Reference
26
Status change
Status change running. The information is set with the
following events:
- Start-up in volumetric operation
- Setpoint change in volumetric operation
- Switch to grav. operation. For the time of the monitoring
delay (DR 12)
- defined switch to volumetr. operation upon flow rate fault
27 Reserved
Reserved
28
Dosing active
Switch on material discharge organ
29
Loading active
Loading (belt scale) is activated.
30
Loading complete
Loading (belt scale) is complete.
31 Reserved
Reserved
Table 5-15
DR 30 - Conti-Status flags
5.15.3 DR 30 - Gross Process Value
The current gross weight value. Dimension: Weight Unit [WU].
5.15.4 DR 30 - Net Process Value
The current net weight value. Dimension: Weight Unit [WU].
5.15.5 DR 30 - Tare Process Value
The current tare weight value. Dimension: Weight Unit [WU].
5.15.6 DR 30 - G/N Weight
The momentary weight value which will be used for the main display. Dimension:
Weight Unit [WU].
5.15.7 DR 30 - G/N Weight_x10
The momentary weight value in increased resolution which will be used for the
main display. Dimension: Weight Unit [WU].
5.15.8 DR 30 - Tare
The current weight value tare (numeral step from DR 3). Dimension: Weight Unit [WU].
5.15.9 DR 30 – Belt Speed
The current belt speed defined in length units (e.g. m) per second.
5.15.10 DR 30 – Belt Speed in % of the Nominal Speed
The current belt speed in % of the predefined nominal speed.
5.15.11 DR 30 – Belt Loading in % of the Nominal Load
The current belt load is output as the relationship of the current belt load to the
nominal belt load.
5-76