Rated current
0.5 A
Max. output current
0.6 A
max. cumulative current of all outputs
2 A
Isolation
500
V
Voltage drop on assembly
< 0.25 V
Switching delay
≤
12 ms
Short-circuit proof
Yes
1
1
Pulsed output current upon short-circuit
Table 14-5
Data: Digital inputs, Digital outputs
14.6 Counter Input CI (for belt scale)
Number 1
Rated voltage
DC 24 V
Isolation
conforming with IEC 1131, UL 508,
CSA C22.2 NO. 142
500 V
Voltage range for H signal
DC 9 V to 30 V
Voltage range for L signal
DC -3 V to 5 V
Input current (15 to 30 V)
2 to 15 mA
Switching frequency
max. 10 kHz
Isolation
500 V
Table 14-6
Data: Counter input CI
14.7 RS 232C Interface
Baud rate
1200 to 115200 Baud
Data bits
8
Parity Even
Stop bits
1
Max. distance
15 m
Signal level
Conforms to EIA-RS232C
Isolation
500 V
Table 14-7
Data: RS 232C interface
14.8 RS 485 Interface
Baud
rate
1200 to 19200 Baud
Data bits
7 or 8
Parity
even / odd
Stop bits
1 or 2
Max. distance
1000m at 1200 Baud
Signal level
Conforms with EIA-RS485
Termination resistance
390
Ω
/ 220
Ω
/ 390
Ω
Isolation
500 V
Table 14-8
Data: RS 485 interface
14-128
SIWAREX FTC
Содержание SIWAREX FTC
Страница 1: ...SIWAREX FTC Device Manual Status 10 2010 Module for Belt scale ...
Страница 12: ......
Страница 134: ...11 Empty 11 122 SIWAREX FTC ...