W
EIGHING
F
UNCTIONS AND
P
ARAMETERS
5.4.10 DR 4 - Cut-off Weight Limit Value 2
See: Switch On Weight, Limit Value 1
5.4.11 DR 4 - Switch-on Weight Limit Value 3
The switch-on and cut-off weight can be defined separately for the limit value.
With limit value 3, only the maximum weight monitor can be used. The basis weight
for the limit value 3 is always the gross weight.
5.4.12 DR 4 - Cut-off Weight Limit Value 3
When the limit value is undercut, the status information "limit value 3) is reset.
5.5 DR 5 Belt Scale Parameter
The basis parameter for belt scale defines other features of a scale which are
responsible for the behavior in the belt scale operating mode. The parameter must
be checked and changed in some cases.
Procedure:
o
Check all parameters and change if necessary.
o
Send the DR 5 to the scale
Name
Type
Address
Default
Range of Values / Meaning
Reference
Nominal speed
REAL DBD000
0
Nominal speed of the belt in LU/s (Length
units per second)
Time basis for belt
speed
TIME
DBD004
0
Time basis for measuring the belt speed by
impulse counter input (msec)
Pulse constant
REAL
DBD008
0
Pulse constant of the speed sensor
Constant belt speed
REAL
DBD012
2000
Constant speed if no speed sensor is
connected.
0 – for connecting the speed sensor.
Minimum belt speed
INT
DBW016
800
Limit value for minimum belt speed in % of
the nominal speed.
800 corresponds with 80.0 %
Maximum belt speed
INT
DBW018
1020
Limit value for maximum belt speed in % of
the nominal speed.
1020 corresponds with 102.0 %
Reaction time for belt
monitor
At start
TIME DBD020
Reaction
time
for belt monitoring and belt
cycle error message at belt start
Reaction time for belt
monitor
During operation
TIME DBD024
Reaction
time
for belt monitoring and belt
cycle error message during belt operation
Reserve_5_28 REAL
DBD028
Reserved
Nominal flow-rate
REAL
DBB032
Nominal flow-rate in weight units / s
Effective belt length
REAL
DBB036
Effective belt length in length units LU
Correction factor for
flow-rate
REAL
DBB040
Correction factor for the flow rate
Minimum flow-rate
INT
DBD044
Limit value for minimum flow-rate in % of the
nominal flow-rate
Maximum flow-rate
INT
DBD046
Limit value for maximum flow-rate in % of the
nominal flow-rate
SIWAREX FTC