Name
Type
Address
Default
Range of Values / Meaning
Reference
Maximum weight for
weighing range 1
REAL
DBD062 100
Numeral step for
weighing range 1
REAL
DBD066
0,02
Number step weighing range 1 (1*10
k
, 2*10
k
,
5*10
k
, k
∈
N
0)
Other definitions not permitted.
Minimum weight for
Weighing range 2
REAL
DBD070 0
Maximum weight for
weighing range 2
REAL
DBD074 0
Numeral step for
weighing range 2
REAL
DBD078 0
Number step WB2 (1*10
k
, 2*10
k
, 5*10
k
, k
∈
N
0)
Other definitions not permitted.
Minimum weight for
Weighing range 3
REAL
DBD082 0
Maximum weight for
weighing range 3
REAL
DBD086 0
Numeral step for
weighing range 3
REAL
DBD090 0
Numeral step WB3 (1*10
k
, 2*10
k
, 5*10
k
, k
∈
N
0)
Other definitions not permitted.
(3) Calibration parameter
III
Standstill Time
TIME DBD094
1000
ms
Standstill Range
REAL
DBD098
0,02
Standstill range in weight unit
Wait time for standstill
TIME
DBD102
2000
If there is no standstill, the weighing command
is immediately rejected with an operating error
at setting 0 and otherwise the wait time is
waited through. If no standstill has occurred
after the wait time has elapsed, an error
message is generated and the command is
aborted. For weighing commands (zero setting,
taring in operation as non-automatic weighing
instrument) that are activated by an operator, a
setting in the 2000 ms range is a good idea.
Max. negative weight for
zero setting when
switching on
BYTE
DBB106
10
Neg. Range of the switch-on zero setting device
[in % of WB
max
]
(Entry from Pos- + Neg. Zero setting value may
not exceed 20% for country code „OIML“)
Deactivated for loss-in-weight scale.
Max. positive weight for
zero setting when
switching on
BYTE
DBB107
10
Pos. range for switch-on zero setting device [in
% of WB
max
]
(Entry from Pos- + Neg. Zero setting value may
not exceed 20% for country code „OIML“)
Deactivated for loss-in-weight scale.
Maximum negative
weight for zero setting
BYTE
DBB108
1
Neg. Range of zero setting device [in % of
WB
max
]
(Entry from Pos- + Neg. Zero setting value may
not exceed 4% for country code „OIML“)
Maximum positive weight
for zero setting
BYTE
DBB109
3
Neg. Range of zero setting device [in % of
WB
max
]
(Entry from Pos- + Neg. Zero setting value may
not exceed 4% for country code „OIML“)
Tare max. weight T-
BYTE
DBB110
100
Subtractive tare device range
[in % of WB
max
with multi-range scale]
[in % of WB
1
with multi-resolution scale]
(Entry may not exceed 100% with country code
"OIML")