T
ECHNICAL
D
ATA
Load cell power Voltage
Current
Typical DC 10.2 V *
≤
184 mA
Permitted load cell resistance without Ex-i-Interface > 56
Ω
< 4010
Ω
Permitted load cell resistance with Ex-i-Interface
> 87
Ω
< 4010
Ω
Monitor for sensor inputs
Typical
≥
5 V
Hysteresis 120 mV
Response time for sensor line monitor
≤
1 s
Common mode rejection CMRR @50 Hz
Typical 120 dB
Measuring value filtering for low pass filter
0.05...20 Hz
Measured value filtering for average value filter
2...250 values
Impedance measurement for load cells
Measuring range 56
Ω
...4010
Ω
Precision ±5%
Repeat accuracy <1 %
Isolation
500 V
* Values apply to module output
Table 14-3
Data: Load Cell Connection
14.4 Analog Output
The defined replacement value is output for active BASP-/OD signal
(S7 CPU).
Range 1
0 to 20 mA
Range 2
4 to 20 mA
Max. total error at 25 °C
< 0,5 % *
Refresh rate
10 ms
Load (incl. line resistance)
≤
520
Ω
,
≤
30 nF
Cable length 0.5 mm
2
200
m
Temperature coefficient
max. ± 75 ppm / K
Resolution
12 Bit (4096 parts) **
Isolation
500 V
* Definitions apply with current >0.5mA
** Resolution reduced by 20 % with operations 4 to 20 mA
Table 14-4
Data: Analog Output
14.5 Digital Inputs (DI), Digital Outputs (DO)
The defined value is always output on the DO for active BASP-/OD
signal (S7 CPU).
An inverse diode (recovery diode) is to be used on the consuming
component with inductive loads on the DO.
DI
DO
Number 7
8
Rated voltage
DC 24 V
Isolation
500 V
Voltage range for H signal
DC 15 V to
30 V
Voltage range for L signal
DC -3 V to
5 V
Input current (15 to 30 V)
2 to 15 mA
Switching frequency
max. 50 Hz max. 50 Hz
SIWAREX FTC
14-127