![Siemens SIWAREX FTC Скачать руководство пользователя страница 81](http://html.mh-extra.com/html/siemens/siwarex-ftc/siwarex-ftc_device-manual_1265490081.webp)
W
EIGHING
F
UNCTIONS AND
P
ARAMETERS
Name
Type
Address Default
Range of Values / Meaning
Reference
Date / Time
Date / Time
DATE_AN
D_TIME,
DT
DBD000 01.01.01
00:00:00
000 Mo
Date&Time in SIMATIC-Format
4
Table 5-5
Allocation of DR 8
5.8 DR 9 Info on Module
No entries can be made in DR 9. The data record uses the information on the inner
life of the module.
Name
Type
Address Default
Range of Values / Meaning
Reference
Info on module
CRC Checksum
DWORD DBW000
0
-
Length of firmware in
bytes
DWORD DBW004
0
-
Product Info
STRING
[26]
DBB008
0
Siemens AG Serial number of the module
Module name
STRING
[10]
DBB036
SIWAREX
XX
„CONT“
„NAWI“
„xxxx“
Application
STRING
[4][8]
DBB048
„xxxx“
„xxxx“
„xxxx“
„xxxx“
„xxxx“
Application identification
File name
STRING
[20]
DBB082 0
Version recognition
Function status
Data structure version
Correction status
BYTE
[4]
DBB104
0
Byte 0 (ASCII)
Before delivery approval
B = Laboratory status
P = Pilot
R = Release
S = Special status
After delivery approval
V = Version
K = Correction status
Byte 1 function status xx (important function
changes or technical changes for the calibration
0 ... 99)
Byte 2 Version DR structure yy (indicates
changes in the data record structure) 0 ... 99
Byte 3 correction status zz (small changes or
error clean-up) 0 ... 99
Creation date
STRING
[10]
DBB108 0
Creation time
STRING
[8]
DBB120 0
SIWAREX FTC
5-69
Содержание SIWAREX FTC
Страница 1: ...SIWAREX FTC Device Manual Status 10 2010 Module for Belt scale ...
Страница 12: ......
Страница 134: ...11 Empty 11 122 SIWAREX FTC ...