Table 11-12 Current output (Channels 2 to 4)
Description
Channels 2 to 4
Signal range
0/4 to 20 mA
Resolution
0.4 μA
Load
● Ex i: <470 Ω
● Non-Ex: <770 Ω
Time constant (adjustable)
0.0 to 100 s
Fault current
Measurement range (mA)
Lower fault current (mA)
Upper fault current (mA)
4-20 NAMUR
3.8 - 20.5
3.5
22.6
4-20 US
4.0 - 20.8
3.75
22.6
4-20 NAMUR
4.0 - 20.5
2.0
22.0
4-20 US
4.0 - 24.0
2.0
25.0
0-20 NAMUR
0.0 - 20.5
0.0
22.0
0-20 US
0.0 - 24.0
0.0
25.0
Customized fail-safe mode
● Last reliable value
– Lower fault current
– Upper fault current
● Fail-safe value
● Current value
Galvanic isolation
All inputs and outputs are galvanically isolated PELV circuits with 60 V DC isolation from
each other and ground.
Maximum test voltage: 500 V AC
Cable
Standard industrial signal cable with up to 3 twisted pairs with overall screen can be con‐
nected between the transmitter and the control system. Individual pair or overall screen is
optional depending on user requirements.
Voltage range
Max. 24 V DC (active)
14 to 30 V DC (passive)
Table 11-13 Digital output
Description
Channels 2 to 4
Pulse
41.6 µs to 5 s pulse duration
Resolution
1 μs
Frequency
0 to 12.5 kHz, 50 % duty cycle, 120 % overscale provision
Resolution
0.2 Hz
Load
< 750 Ω
Time constant (adjustable)
0 to 100 s
Active
0 to 24 V DC, 87 mA, short-circuit-protected
Passive
3 to 30 V DC, 100 mA, short-circuit-protected
Functions
● Pulse
● Frequency
● Alarm class / NAMUR status
● Individual alarms
Technical data
11.5 Outputs
SITRANS FC330
Operating Instructions, 01/2019, A5E44030648-AB
199
Содержание SITRANS FC330
Страница 14: ...Introduction 1 8 Notes on warranty SITRANS FC330 14 Operating Instructions 01 2019 A5E44030648 AB ...
Страница 56: ...Installing mounting 4 3 Disassembly SITRANS FC330 56 Operating Instructions 01 2019 A5E44030648 AB ...
Страница 126: ...Operating 7 2 Remote operation SITRANS FC330 126 Operating Instructions 01 2019 A5E44030648 AB ...
Страница 158: ...Parameter assignment 8 2 Functions SITRANS FC330 158 Operating Instructions 01 2019 A5E44030648 AB ...
Страница 216: ...Technical data 11 13 Pressure temperature ratings SITRANS FC330 216 Operating Instructions 01 2019 A5E44030648 AB ...
Страница 224: ...Dimension drawings 12 7 Mounting bracket dimensions SITRANS FC330 224 Operating Instructions 01 2019 A5E44030648 AB ...
Страница 236: ...HART communication B 1 Mode of operation HART function SITRANS FC330 236 Operating Instructions 01 2019 A5E44030648 AB ...
Страница 274: ...Zero point adjustment SITRANS FC330 274 Operating Instructions 01 2019 A5E44030648 AB ...
Страница 280: ...Index SITRANS FC330 280 Operating Instructions 01 2019 A5E44030648 AB ...