2 Functions
72
7SD5 Manual
C53000-G1176-C169-1
352
>CB Aux. L2
SP
>Circuit breaker aux. contact: Pole L2
353
>CB Aux. L3
SP
>Circuit breaker aux. contact: Pole L3
356
>Manual Close
SP
>Manual close signal
357
>CloseCmd.Blo
SP
>Block all close commands from external
361
>FAIL:Feeder VT
SP
>Failure: Feeder VT (MCB tripped)
362
>FAIL:Bus VT
SP
>Failure: Busbar VT (MCB tripped)
366
>CB1 Pole L1
SP
>CB1 Pole L1 (for AR,CB-Test)
367
>CB1 Pole L2
SP
>CB1 Pole L2 (for AR,CB-Test)
368
>CB1 Pole L3
SP
>CB1 Pole L3 (for AR,CB-Test)
371
>CB1 Ready
SP
>CB1 READY (for AR,CB-Test)
378
>CB faulty
SP
>CB faulty
379
>CB 3p Closed
SP
>CB aux. contact 3pole Closed
380
>CB 3p Open
SP
>CB aux. contact 3pole Open
381
>1p Trip Perm
SP
>Single-phase trip permitted from ext.AR
382
>Only 1ph AR
SP
>External AR programmed for 1phase only
383
>Enable ARzones
SP
>Enable all AR Zones / Stages
385
>Lockout SET
SP
>Lockout SET
386
>Lockout RESET
SP
>Lockout RESET
410
>CB1 3p Closed
SP
>CB1 aux. 3p Closed (for AR, CB-Test)
411
>CB1 3p Open
SP
>CB1 aux. 3p Open (for AR, CB-Test)
501
Relay PICKUP
OUT
Relay PICKUP
502
Relay Drop Out
OUT
Relay Drop Out
503
Relay PICKUP L1
OUT
Relay PICKUP Phase L1
504
Relay PICKUP L2
OUT
Relay PICKUP Phase L2
505
Relay PICKUP L3
OUT
Relay PICKUP Phase L3
506
Relay PICKUP E
OUT
Relay PICKUP Earth
507
Relay TRIP L1
OUT
Relay TRIP command Phase L1
508
Relay TRIP L2
OUT
Relay TRIP command Phase L2
509
Relay TRIP L3
OUT
Relay TRIP command Phase L3
510
Relay CLOSE
OUT
General CLOSE of relay
511
Relay TRIP
OUT
Relay GENERAL TRIP command
512
Relay TRIP 1pL1
OUT
Relay TRIP command - Only Phase L1
513
Relay TRIP 1pL2
OUT
Relay TRIP command - Only Phase L2
514
Relay TRIP 1pL3
OUT
Relay TRIP command - Only Phase L3
515
Relay TRIP 3ph.
OUT
Relay TRIP command Phases L123
530
LOCKOUT
IntSP
LOCKOUT is active
533
IL1 =
VI
Primary fault current IL1
534
IL2 =
VI
Primary fault current IL2
535
IL3 =
VI
Primary fault current IL3
536
Final Trip
OUT
Final Trip
545
PU Time
VI
Time from Pickup to drop out
546
TRIP Time
VI
Time from Pickup to TRIP
560
Trip Coupled 3p
OUT
Single-phase trip was coupled 3phase
561
Man.Clos.Detect
OUT
Manual close signal detected
562
Man.Close Cmd
OUT
CB CLOSE command for manual closing
563
CB Alarm Supp
OUT
CB alarm suppressed
No.
Information
Type of In-
formation
Comments
www
. ElectricalPartManuals
. com
Содержание siprotec 7SD5
Страница 2: ...2 7SD5 Manual C53000 G1176 C169 1 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 4: ...4 7SD5 Manual C53000 G1176 C169 1 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 18: ...Contents 18 7SD5 Manual C53000 G1176 C169 1 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 34: ...1 Introduction 34 7SD5 Manual C53000 G1176 C169 1 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 444: ...2 Functions 444 7SD5 Manual C53000 G1176 C169 1 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 580: ...4 Technical Data 580 7SD5 Manual C53000 G1176 C169 1 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 682: ...Literature 682 7SD5 Manual C53000 G1176 C169 1 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 698: ...Index 698 7SD5 Manual C53000 G1176 C169 1 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...