Dropout time
27
Capacitive load (supply-line capaci-
tance)
Dropout time
< 5 nF
< 3 ms
< 10 nF
< 4 ms
< 50 nF
< 5 ms
< 220 nF
< 10 ms
Control voltage for the module
IO216
Range for 220 V control voltage
Threshold pickup
158 V to 170 V
Threshold dropout
132 V to 154 V
Maximum permitted voltage
DC 300 V
The binary inputs contain interference suppression capacitors. To ensure EMC immunity, use the terminals
shown in the terminal diagrams/connection diagrams to connect the binary inputs to the common potential.
Relay Outputs
Standard Relay (Type S)
Making capacity
Max. 1000 W (L/R = 40 ms)
Max. 3600 VA (power factor ≤ 0.35, 50 Hz to 60 Hz)
Breaking capacity
Max. 30 W (L/R = 40 ms)
Max. 360 VA (power factor ≤ 0.35, 50 Hz to 60 Hz)
AC and DC contact voltage
250 V
Permissible current per contact (continuous)
5 A
Permissible current per contact (switching on and
holding)
30 A for 1 s (make contact)
Short-time current across closed contact
250 A for 30 ms
Total permissible current for contacts connected to
common potential
5 A
Switching time OOT (Output Operating Time)
Additional delay of the output medium used
Make time: typical: 8 ms; maximum: 10 ms
Break time: typical: 2 ms; maximum: 5 ms
Max. rated data of the output contacts in accordance
with UL certification
DC 24 V, 5 A, General Purpose
DC 48 V, 0.8 A, General Purpose
DC 240 V, 0.1 A, General Purpose
AC 240 V, 5 A, General Purpose
AC 120 V, 1/6 hp
AC 250 V, 1/2 hp
B300
R300
Interference suppression capacitors across the
contacts
4.7 nF, ± 20 %, AC 250 V
Fast Relay (Type F)
Making capacity
Max. 1000 W (L/R = 40 ms)
Max. 3600 VA (power factor ≤ 0.35, 50 Hz to 60 Hz)
Breaking capacity
Max. 30 W (L/R = 40 ms)
Max. 360 VA (power factor ≤ 0.35, 50 Hz to 60 Hz)
AC and DC contact voltage
250 V
12.1.4
27
For time-critical applications with low-active signals, consider the specified dropout times. If necessary, provide for active discharge
of the binary input (for example, a resistor in parallel to the binary input or using a change-over contact).
Technical Data
12.1 General Device Data
SIPROTEC 5, Merging Unit 6MU85, Manual
793
C53000-G5040-C074-1, Edition 01.2020