Configuring the HMI system
2.4 Simulation
HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
75
●
Global work offsets
●
Setting data (SEA)
●
Global setting data
●
Axis-specific setting data
●
Protection zones (PRO)
●
Sag/angularity (CEC)
The data can be selected in any combination. The channels are selected using softkeys (if
there is more than one channel for simulation); the current channel of the simulation is
offered as default. Channel-specific data are only offered if the selected channel is present
on the NCK. The selected data are copied into corresponding files in the data management
system under \DP.DIR\SIM.DIR using the "OK" softkey and loaded into the simulation.
Existing files are overwritten without prompting.
If data are selected for all channels, any associated channel-specific files that are present
are deleted; channel-specific files are always created or overwritten.
Before the data are loaded into the simulation, a "channel reset" is performed for the
simulation.
If an error occurs when copying from the NCK, the transfer can be repeated or aborted
(dialog box: Abort/Repeat). If an error occurs when loading into the simulation or a simulation
alarm is triggered, the transfer is aborted.
Pressing the "OK" softkey saves the current data selection and displays it again the next
time the dialog box is opened.
Match tools
The NC tool data for all channels are copied into the TO_INI.INI file and then activated in the
simulation. Existing tools are removed beforehand. The function is offered automatically
whenever simulation is selected if tool data in the NC have changed.
Match machine data
All definition files (UMAC.DEF, SMAC.DEF, MMAC.DEF, UGUD.DEF, SGUD.DEF,
MGUD.DEF, GUD4.DEF – GUD9.DEF) that are active in the NC are copied to the
corresponding files in the HMI. Files that are not active in the NCK are deleted from the HMI.
All files (CH(c)_xxx.INI, AX_SEA.INI, NC_xxx.INI) are deleted with the exception of the tool
data.
The machine data from the INITIAL.INI file are interpreted by the simulation. We recommend
to set the following machine data:
MD 11210: UPLOAD_MD_CHANGES_ONLY = 0
Match cycles
Cycle changes are not monitored by the simulation.
They are either copied automatically into the simulation as required (PRELOAD/CYCLES=0)
or copied in their entirety into the simulation when the simulation boots.
Содержание SINUMERIK
Страница 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 24: ...Introduction 1 5 Limits of data management HMI Advanced IM4 18 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 96: ......
Страница 338: ...List of Abbreviations B 1 Abbreviations HMI Advanced IM4 332 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 464: ...Programming 2 8 Operators Expanding the user interface 2 114 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...
Страница 638: ...References for text generation Generating target language texts TX2 40 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 672: ...Commissioning a system 1 4 BIOS settings PCU Basesoftware IM8 32 Commissioning Manual 03 2009 6FC5397 1DP10 4BA0 ...