Tool management
6.1 Setting tool management parameters on the HMI
HMI Advanced (IM4)
172
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
Locations
Name
Enter or select the name of the buffer.
Display text
Language-dependent name of the magazine
If it exists, the display text is immediately displayed from patm_xx.ini.
Number
Display of the current magazine number
Type
Selection of buffer type (spindle/toolholder, gripper, transfer location, loader)
Index
The index counts the locations of a type.
Number
Display of the consecutive internal number under which the location is to be
addressed
Overview
The number of all buffer locations is displayed as a graph.
In addition, the currently selected buffer location (No.) is highlighted. Each "type"
is displayed in a different color.
Note
The sequence must be adhered to when entering the buffer. The spindles must always be
entered first. A number is assigned internally for each buffer location, via which the buffer
location is addressed.
The buffer "spindle" with index 1 and spindle_1 in the NC have a direct relationship to one
another. This means that for example the "spindle" buffer with index 1 must also be the 1st
spindle for the NC, index 2 = 2nd spindle.
Creating a buffer location
Follow the steps outlined below:
1.
Press the "New" softkey.
2.
Enter a name: e.g. Gripper_1. If it exists, the display text is immediately displayed from
patm_xx.ini.
3.
Select the type: Transfer location, gripper, loader, spindle
4.
The buffer location is created by pressing "OK", the location number and the index are
internally assigned and incremented.
Assigning / deassigning a spindle:
1.
The "Assign spindle" softkey assigns a buffer location (e.g. gripper) to a spindle. This
informs the software of the mechanical relation between the gripper and spindle.
2.
The "Deassign spindle" softkey cancels an existing spindle assignment.
3.
Assigning/removing buffer locations to/from the magazines
4.
When a magazine is selected, the distance to the change position must be entered. At
least 0 must be entered, as otherwise the tool cannot be transported to this buffer
location. The "Assign magazine" softkey assigns the buffer location to the magazine.
5.
The "Deassign magazine" softkey cancels an existing assignment of a buffer location to a
magazine.
Содержание SINUMERIK
Страница 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 24: ...Introduction 1 5 Limits of data management HMI Advanced IM4 18 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 96: ......
Страница 338: ...List of Abbreviations B 1 Abbreviations HMI Advanced IM4 332 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 464: ...Programming 2 8 Operators Expanding the user interface 2 114 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...
Страница 638: ...References for text generation Generating target language texts TX2 40 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 672: ...Commissioning a system 1 4 BIOS settings PCU Basesoftware IM8 32 Commissioning Manual 03 2009 6FC5397 1DP10 4BA0 ...