Programming PLC Functions
4.1 Activating the data transfer between the PLC and NCK
HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
115
Note
This function is not available if the "Machine" operating area is suppressed from the
HMI startup.
Error IDs at the PLC
The HMI outputs the following error IDs to the PLC via DB19.DBB27:
Value
Significance
0
No error
1
Invalid number for control file. (value in DB19.DBB16 < 127 or invalid)
2
Unable to read DB19.DBB15
3
Control file /BD.DIR/PLC_IN_OUT_xxx.TEA not found. (value in DB19.DBB16 invalid)
4
Invalid index in control file. (incorrect value in DB19.DBB17)
5
Selected job list in control file could not be opened.
6
Error in job list (job list interpreter returns error)
7
Job list interpreter returns empty job list
9
Error while executing job list
Conflict resolution
When a job list is executed manually (via operator input), prompts can occur in the protocol,
e.g. if an MPF file is located both on the NC as well as on a hard disk and the two MPF files
are different.
The default setting is "yes," i.e., all prompts are responded to with Yes. If "no", all prompts
are responded to with No. The default setting for the response is "yes", i.e., all prompts are
responded to with Yes. If "no", all prompts are responded to with No. The response to the
prompt is set in the file MASCHINE.INI:
[PLC_REQUEST]
DefaultAnswer=yes
Multiple operator panel fronts/NCUs M:N (only SINUMERIK powerline)
In an m:n system, HMI-Advanced is assigned to a netmaster NCU/PLC in NETNAMES.INI.
The bus address of the NCU is configured in the [param network] section.
e.g.: [param network]
netmaster=NCU_LINKS
This setting for the netmaster NCU/PLC means that data transfer is only activated by the
NCU/PLC with the symbolic name NCU_LEFT.
Содержание SINUMERIK
Страница 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 24: ...Introduction 1 5 Limits of data management HMI Advanced IM4 18 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 96: ......
Страница 338: ...List of Abbreviations B 1 Abbreviations HMI Advanced IM4 332 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 464: ...Programming 2 8 Operators Expanding the user interface 2 114 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...
Страница 638: ...References for text generation Generating target language texts TX2 40 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 672: ...Commissioning a system 1 4 BIOS settings PCU Basesoftware IM8 32 Commissioning Manual 03 2009 6FC5397 1DP10 4BA0 ...