Configuring the HMI system
2.1 Processing INI files
HMI Advanced (IM4)
22
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
Switching off settings
If, for the search sequence, there are specific entries in a lower-priority directory that you
wish to be disabled in a directory with a higher-priority, you can do this by specifying an
<empty> entry instead of a value.
Example:
Directory mmc2, file xxx.INI:
[<Section>]
<Identifier> = <value>
Directory user, file xxx.INI:
[<Section>]
<Identifier> = <empty>
Maximum file length
The maximum file length for INI files in Windows systems is 60 kbytes. If this limit is
exceeded, entries at the end are ignored.
Remedy: Omit the full comments in \USER\PARAMT.INI, for example, since they are also
included in MMC2\PARAMT.INI.
2.1.1
Terminate OEM commissioning
Function
This function transfers the initialization data from the USER directory to the OEM directory.
This provides the user with an empty USER directory and deletes any existing initialization
files (*.ini) stored there, without losing the settings it contains because the initialization files
are taken out of the USER directory and put in the OEM directory. If no OEM directory is
available one is created automatically, if initialization files are stored in the USER directory.
Combine all INI files:
1.
If you wish to accept all initialization files, press the "Terminate OEM st.-up" softkey. The
following message will appear: "Combine all initializing files (*.ini) from the USER
directory with the relevant files of the OEM directory."
2.
Press the "Save" softkey to start data transmission.
Existing entries in the OEM directory are overwritten by the corresponding entries from
the USER directory.
3.
New files are created.
Files which do not appear in the USER directory, but already exist in the OEM directory,
are saved. During transmission the name of each file is displayed in the status bar. Once
all of the data has been transmitted successfully the file is deleted from the USER
directory.
Содержание SINUMERIK
Страница 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 24: ...Introduction 1 5 Limits of data management HMI Advanced IM4 18 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 96: ......
Страница 338: ...List of Abbreviations B 1 Abbreviations HMI Advanced IM4 332 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 464: ...Programming 2 8 Operators Expanding the user interface 2 114 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...
Страница 638: ...References for text generation Generating target language texts TX2 40 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 672: ...Commissioning a system 1 4 BIOS settings PCU Basesoftware IM8 32 Commissioning Manual 03 2009 6FC5397 1DP10 4BA0 ...