Tool management
6.2 Settings in the configuration file
HMI Advanced (IM4)
234
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
User-defined bitmaps can be stored in the "user" directory. They are displayed instead of the
standard bitmaps in the lists.
Handling of lists
The columns of the lists in which the bitmaps are to be entered can be set for each list view.
The width of the bitmaps is set in characters for the entire highlighted areas. The width of the
column is automatically increased by the value set.
Bitmaps overwrite mutually when displayed in the same column and line. The highlighting at
the top represents the current tool, the highlighting below represents the programmed tool
and the highlighting at the bottom represents the current location. Hidden bitmaps are not
displayed.
Note
In multi-line magazine and tool lists, the highlighting is entered in the cutting edge line when
the current/programmed DNo./cutting edge no. <> 0. The same applies in working offset lists
for DLNo. <> 0 for the DL rows. Since only cutting edges can be displayed in the views of the
working offset lists, the highlighting only appears if the current/programmed DNo./cutting
edge no. <> 0.
The current magazine location is only highlighted in the magazine list views. Highlighting
only appears in the normal magazine display and not in the buffer magazine display.
Setting the bitmap parameters
By default, the bitmaps are not entered in paramtm.ini and are not displayed. If the bitmaps
are to be displayed in the lists, you will have to make some changes to the parameter file.
One entry is required for each bitmap.
Entries in paramtm.ini:
[GeneralSettingForMagAndToolList]
; Width of the bitmap display
; Unit: number of characters
WidthOfActBitmapsInCharacters=5
; Name of the bitmap for the current tool /DNo./DL,
; where D<>0 and DL<>0
ActToolBitmap=paat.bmp
; Name of the bitmap for the current tool/DNo.,
; if the current cutting edge D=0.
ActToolZeroDBitmap=paatd0.bmp
; Name of the bitmap for the current tool /DNo./DL,
; if the current DL=0.
ActToolZeroDLBitmap=paatdl0.bmp
; Name of the bitmap for the programmed tool /DNo./DL,
; where D<>0 and DL<>0
ProgToolBitmap = papt.bmp
; Name of the bitmap for the programmed tool/DNo.,
Содержание SINUMERIK
Страница 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 24: ...Introduction 1 5 Limits of data management HMI Advanced IM4 18 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 96: ......
Страница 338: ...List of Abbreviations B 1 Abbreviations HMI Advanced IM4 332 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 464: ...Programming 2 8 Operators Expanding the user interface 2 114 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...
Страница 638: ...References for text generation Generating target language texts TX2 40 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 672: ...Commissioning a system 1 4 BIOS settings PCU Basesoftware IM8 32 Commissioning Manual 03 2009 6FC5397 1DP10 4BA0 ...