Commissioning a system
1.3 Boot up behavior of the PCU
PCU-Basesoftware (IM8)
Commissioning Manual, 03/2009, 6FC5397-1DP10-4BA0
25
Settings
Meaning
Example 2: There is no PCU panel, however there is a PCU monitor (irrespective of
whether there are any TCU panels):
[in active TCU mode:
The following additional condition applies: PCU is activated (with dynamic
resolution switching enabled)]:
The resolution is not specially set; i.e., the resolution last used in the
system is active, e.g., the resolution which had been set manually in the
Control Panel.
(Different to AUTO_OP_2 !)
AUTO_OP_2
Like AUTO_OP_1, except:
Example 2: There is no PCU panel, however there is a PCU monitor
(irrespective of whether there are any TCU panels):
[in active TCU mode:
The following additional condition applies: PCU is activated (with dynamic
resolution switching enabled)]:
The resolution is set to the max. resolution of the PCU monitor, reduced to
the next lowest SINUMERIK resolution. The SINUMERIK resolutions are
640x480, 800x600, 1024x768 and 1280x1024.
Example: In the case of a PCU monitor with a max. resolution of 1440x900,
the SINUMERIK resolution setting is 1280x1024.
AUTO_MON_1
During boot up, the resolution is automatically set ("PCU monitor" has
priority) in accordance with the following scenarios:
Example 1: There is a PCU monitor (irrespective of whether there is a PCU panel and
TCU panels)
[in active TCU mode:
The following additional condition applies: PCU is activated (with dynamic
resolution switching enabled)]:
The resolution is set to the max. resolution of the PCU monitor, reduced to
the next lowest SINUMERIK resolution. The SINUMERIK resolutions are
640x480, 800x600, 1024x768 and 1280x1024.
Example: In the case of a PCU monitor with a max. resolution of 1440x900,
the SINUMERIK resolution setting is 1280x1024.
If there is a PCU panel, the display there is panned if the max. resolution of
the PCU panel is lower than the max. resolution of the PCU monitor.
Example 2: There is no PCU monitor, however there is a PCU panel (irrespective of
whether there are any TCU panels):
[in active TCU mode:
The following additional condition applies: PCU is activated (with dynamic
resolution switching enabled)]:
The resolution is not specially set; i.e., the resolution last used in the
system is active, e.g., the resolution which had been set manually in the
Control Panel.
(Different to AUTO_MON_2 !)
Содержание SINUMERIK
Страница 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 24: ...Introduction 1 5 Limits of data management HMI Advanced IM4 18 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 96: ......
Страница 338: ...List of Abbreviations B 1 Abbreviations HMI Advanced IM4 332 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 464: ...Programming 2 8 Operators Expanding the user interface 2 114 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...
Страница 638: ...References for text generation Generating target language texts TX2 40 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 672: ...Commissioning a system 1 4 BIOS settings PCU Basesoftware IM8 32 Commissioning Manual 03 2009 6FC5397 1DP10 4BA0 ...