SINAUT MD720-3 in Terminal Mode
SINAUT MD720-3
56
C79000-G8976-C211
AT+KHNDVR
Selecting mobile / stationary operation
Read command
Command:
+ KHNDVR?
Response:
+ KHNDVR <stat>
Executive command
Command:
+ KHNDVR=<stat>
Response: OK
Parameter: <stat>:
0:
Setting for data calls (CSD 9600 Bit/s) in mobile operation
1:
Setting for data calls (CSD 9600 Bit/s) in stationary operation
Notice:
The command has no impact to GPRS connections or the sending of SMS. In mobile
operation <stat> must be set to zero.
Composed AT commands
The initialization strings below are accepted by the SINAUT MD720-3. The reaction
to the separate commands correspondingly.
TIM device
ATE0S0=1&D2+CBST=71,0,1;+CRC=1;&W+IPR=19200
S7-2xx-device
ATE0S0=0+IPR=9600
Other initialization strings
AT+CMGF=1+CSMP=17,0,0,0+CSCA="+AAAAAAAAAAA"
AT+CMGS="+
BBBBBBBBBB
",145