SINAUT MD720-3 in Terminal Mode
SINAUT MD720-3
40
C79000-G8976-C211
AT+CGDCONT Define PDP context
Test
Command:
AT+CGDCONT=?
Response:
+CGDCONT: (range of supported <cid>s), <PDP_type>,,,(list of supported <d_comp>s),
(list of supported <h_comp>s)[,(list of supported <pd1>s)[,…[,(list of supported
<pdN>s)]]][...]]
[+CGDCONT: (range of supported <cid>s), <PDP_type>,,,(list of supported <d_comp>s),
(list of supported <h_comp>s)[,(list of supported <pd1>s)[,…[,(list of supported
<pdN>s)]]][...]]] OK
Read command
Command:
AT+CGDCONT?
Response:
If +CGDCONT is set:
+CGDCONT: <cid>, <PDP_type>, <APN>,<PDP_addr>, <d_comp>,
<h_comp>[,<pd1>[,…[,pdN]]]
[+CGDCONT: <cid>, <PDP_type>, <APN>,<PDP_addr>, <data_comp>,
<head_comp>[,<pd1>[,…[,pdN]]] OK
If +CGDCONT is not set:
OK
Executive command
Command:
+CGDCONT=<cid> ,<PDP_type> ,<APN> ,<PDP_addr> ,<d_comp> ,<h_comp>
Response: OK
Parameter: <cid>:
(Local)
context identification parameter
<PDP_type>:
Packet Data Protocol type
A string parameter which specifies the type of packet data protocol. Only IP Internet
Protocol - IETF STD 5) is supported.
<APN>:
Access Point Name
A string parameter which is a logical name that is used to select the GGSN or the external
packet data network.
<PDP_address>:
A string parameter that identifies the MT in the address space applicable to the PDP. As
only IP is currently supported, it shall be an IP address.
If the value is null (“0.0.0.0” or 0), then a value may be provided by the TE during the PDP
startup procedure or, failing that, a dynamic address will be requested.
The read form of the command will continue to return the null string even if an address
has been allocated during the PDP startup procedure. The allocated address may be
read using the +CGPADDR command.
<d_comp>:
A numeric parameter that controls PDP data compression.
0:
off (default and only value supported)
<h_comp>:
A numeric parameter that controls PDP header compression
0:
off (default and only value supported)
<pd1>, … <pdN>:
Zero to N string parameters whose meanings are specific to the <PDP_type>
Содержание SINAUT MD720-3
Страница 10: ...Contents SINAUT MD720 3 10 C79000 G8976 C211 ...
Страница 22: ...Connecting the device and switching on the device SINAUT MD720 3 22 C79000 G8976 C211 ...
Страница 45: ...SINAUT MD720 3 in Terminal Mode SINAUT MD720 3 C79000 G8976 C211 45 ...
Страница 74: ...Technical Data SINAUT MD720 3 74 C79000 G8976 C211 ...
Страница 76: ...Technical Data SINAUT MD720 3 76 C79000 G8976 C211 ...