SINAUT MD720-3 in Terminal Mode
SINAUT MD720-3
C79000-G8976-C211
41
Notice:
The execute command specifies PDP context parameter values for a PDP context
identified by the (local) context identification parameter, <cid>. The number of PDP
contexts that may be in a defined state at the same time is given by the range returned by
the test command.
A special form of the set command, +CGDCONT= <cid> causes the values for context
number <cid> to become undefined.
AT+CGATT GPRS Attach or Detach
Test
Command:
AT+CGATT=?
Response:
+CGATT: (list of supported <state>s)
Read command
Command:
AT+CGATT?
Response: +CGATT:
<state>
Executive command
Command:
+CGATT=<state>
Response:
OK
Parameter: <state>:
Indicates the state of GPRS attachment
0: detached
1: attached
Notice:
-
AT+CIMI
Request international subscriber identity
Test
Command:
AT+CIMI=?
Response: OK
Read command
Command:
AT+CIMI
Response:
<IMSI> (International Mobile Subscriber Identify)
OK
Parameter: -
Notice: -